Do you have any question about this error?
Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 323
Message text: Consulte la documentación IMG antes de activar las rutinas de gas nat.SAP
Activate SAP conversion routines for natural gas
El sistema emite un mensaje de error y no le permitirá continuar con esta transacción hasta que se resuelva el error.
In order to use the SAP conversion routines for natural gas, you have toThe system continues processing.
To be able to confirm the correctness of the SAP routines, you have to:
1. Check the constants defined in include LOIB_QCITOC.
2. Check the natural gas routines
Approve the following form routines that are located in function
group OIB_QCI:
a) CALCULATE_GAS_BASE_DENSITY (based on ISO 13443, first
edition 1996-12-15)
b) CALCULATE_GAS_BASE_HEATING_VAL (based on ISO 13443, first
edition 1996-12-15)
c) CALCULATE_IDEAL_GAS_VCF (based on ISO 13443, first edition
1996-12-15)
d) CALC_COMBUSTION_CORRECTION (based on ISO 13443, first
edition 1996-12-15)
e) DENSITY_HVALUE_CONVERSION (based on ISO 6976, 1995-12-01,
corrected and reprinted 1996-02-01)
,,Method DETERMINE_AIR_COMP_FAC has to be implemented if base conditions
are used in a conversion ,,group other than the set of conditions
specified in ISO 6976, 1995-12-01, Annex B. This method has to pass the
,,compression factor of air at the new base condition set back to the
form DENSITY_HVALUE_CONVERSION.
3. Check the handling of the results from the AGA C-code routines
(if activated) in form routines ,,DO_EXTERNAL_CALL and
DO_EXTERNAL_CALL_2.
If you decide not to activate the SAP conversion routines, proceed as
follows:
1. Define your own new constants.
2. Implement the following methods if natural gas quantity conversion
has to be performed by the QCI. Each of these 5 routines replace
one of the above-mentioned form routines. The methods are part of the
business add-in OIB_NATURAL_GAS:
a) CALC_BASE_DENSITY
b) CALC_BASE_HEATINGVALUE
c) CALC_IDEAL_GAS_VCF
d) CORR_COMBUSTION_ENERGY
e) DENSITY_HVALUE_CONVERT
The methods can also be used to modify the results from the SAP
conversion routines.
3. Implement method DETERMINE_Z_FACTOR.
If the SAP conversion routines are activated, the SAP system retrieves
the compression factors at ambient and at the base conditions from the
AGA C-code. It calculates a combined volume correction factor by
multiplying the ideal gas volume correction factor with the compression
factor at base conditions and dividing this result by the compression
factor at ambient conditions (material temperature and pressure).
If the SAP conversion routines are not activated, method
DETERMINE_Z_FACTOR is called instead. It imports the results from the
AGA C-code and changes a combined volume correction factor according to
the customer-specific coding.
Extracto de mensaje de error del sistema SAP. Copyright SAP SE.
O3323
- Consulte la documentación IMG antes de activar las rutinas de gas nat.SAP ?Get instant SAP help. Start your 7-day free trial now.
O3322
Tabla interna & no contiene entradas; proceso cancelado; contacte Respons
Mensaje autoexplicativo Dado que SAP cree que este mensaje de error específico 'se explica por sí mismo', no se ha proporcionado más información. ...
O3321
El grupo de conversión ya se ha asignado a una red de distribución activa
¿Qué causa este problema? The conversion group is already assigned to a delivery network. Entries can not be changed.Respuesta del sistema El sist...
O3324
Tabla interna no prevista: &
Mensaje autoexplicativo Dado que SAP cree que este mensaje de error específico 'se explica por sí mismo', no se ha proporcionado más información. ...
O3325
Este set por defecto está activo y no puede modificarse ni borrarse
¿Qué causa este problema? The new default parameter transaction allows you to create default sets for several materials at once. It also introduces...
Haga clic en este enlace para buscar todos los mensajes de SAP.