Do you have any question about this error?
Message type: E = Error
Message class: GP - FI-SL and CO planning
Message number: 714
Message text: La clase de coste & está bloqueada p.centro coste & por planif.detallada
The value of cost element &v1& was already determined for cost center
&v2& in curreny &v3& using detailed planning. A change with the data
transfer is only possible if it is completed by importing or copying a
different detailed planning.
The planned record to be transferred is entered in the error log.
If this message appeared during revaluation, note the following:
Planned values that are created by the detailed planning cannot be
revaluated by the revaluation program; they remain unchanged. Since the
detailed planning also works at the year level, you receive this error
message if you have not selected all periods for revaluation.
If you want to allow the detailed planning to be overwritten by the
normal planning, you can change the type of message in Customizing
using <DS:TRAN.OBA5>transaction OBA5</>.
To do so, proceed as follows:
Enter "GP" as the application area.
For message "714", entere the desired message type for dialog
processing. Use the following codes:
Code Message type
E = Error message
I = Information message
W = Warning
- = No message
El sistema emite un mensaje de error y no le permitirá continuar con esta transacción hasta que se resuelva el error.
Only with type E (standard setting) is the block actually in place.Extracto de mensaje de error del sistema SAP. Copyright SAP SE.
GP714
- La clase de coste & está bloqueada p.centro coste & por planif.detallada ?Get instant SAP help. Start your 7-day free trial now.
GP713
El registro plan ya existe
¿Qué causa este problema? The CO interface has been preconfigured so that existing plan records are not overwritten. &v1& with the key &...
GP712
Planifique los costes fijos y variables con el mismo signo +/-
¿Qué causa este problema? You have transferred total costs to object &V1& and cost element &V2& the amounts of which are smaller th...
GP750
Los regs. incorrectos se cargaron al fichero &.
Mensaje autoexplicativo Dado que SAP cree que este mensaje de error específico 'se explica por sí mismo', no se ha proporcionado más información. ...
GP751
Errores ocurridos en las verificaciones de integración:
Mensaje autoexplicativo Dado que SAP cree que este mensaje de error específico 'se explica por sí mismo', no se ha proporcionado más información. ...
Haga clic en este enlace para buscar todos los mensajes de SAP.