Do you have any question about this error?
Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 256
Message text: Aparato &1: Existen documentos lectura en el futuro; operación rechazada
Meter reading documents exist after the transaction date.
Additional information: When changing the logical register allocation,
or adding/removing a register (if at all, then through the "No meter
reading" indicator), these future meter reading orders cannot be
automatically updated to the modified status. This is only possible for
small modifications (such as number of decimal places, unit of
measurement, and so on).
ELSE
Additional information: A move-in already exists at the installation on
the day of the device replacement. This means that the meter reading
orders have different meter reading reasons to reason 06 (move-in). This
constellation cannot be recognized.
ELSE
Additional information: (At least) one register with a time variable
control group is involved. An automatic adjustment of these future meter
reading orders is not possible.
ELSE
Additional information: (At least) one of the later meter reading orders
is to be interpolated. This is not possible in this context.
ELSE
Additional information: The reassignment of these meter reading
documents to the new device ended with an internal error. One of the
reasons for this could be that the new device does not yet exist in the
database and must be created as a device info record.
ENDIF
Transaction execution is rejected.
You must use the reversal function to delete those meter reading
documents that lie after the transaction date from the meter reading.
Extracto de mensaje de error del sistema SAP. Copyright SAP SE.
EL256
- Aparato &1: Existen documentos lectura en el futuro; operación rechazada ?Get instant SAP help. Start your 7-day free trial now.
EL255
Se han editado &1 de &2 órdenes de lectura
Mensaje autoexplicativo Dado que SAP cree que este mensaje de error específico 'se explica por sí mismo', no se ha proporcionado más información. ...
EL254
Aparato &1 numerador &2: No existe ninguna estimación, ajustar cl.lectura
¿Qué causa este problema? An estimated meter reading was changed. However, the meter reading type was not adjusted. The meter reading type is curre...
EL257
Aparato &1 numer.&2: Corrección no oportuna en caso de error de entrada
¿Qué causa este problema? The system has detected an input error. Since this does not have anything to do with a plausibility check, it does not ma...
EL258
Eror durante la determinación del peso del período base
¿Qué causa este problema? In extrapolation the system attempted to determine the weighting of the base period for register &V1& of device &...