Message type: E = Error
Message class: CPOC - PP-PI-PMA: Process Operator Cockpit Messages
Message number: 138
Message text: Declaración incorrecta de las variables globales &1
Global variables can only be defined and used in <LS>simple data
requests</> at this time. It is <ZH>not </> possible to output whole
tables (<LS>repeated data request
</>) again using global variables.
This can lead to errors in, for example, the following cases:
For live and test control recipes:
If you <ZH>define</> a global variable in a <LS>repeated data request
</> (table) for the same process order in the one control recipe and
then, in a different control recipe, have <ZH>declared</> a <LS>simple
data request</>, the program will terminate when you send the control
recipe.
For test control recipes:
If you have <ZH>declared</> the global variable in a <LS>repeated data
request</> for the same process order in a test control recipe and then
generate a new test control recipe in which you have <ZH>declared</>
the same global variable again in a <LS>simple data request</>, the
program will terminate when you send the second control recipe.
The control recipe cannot be sent. The function is terminated.
Change the declaration of the global variables &V1& in the process
order.
You can use indexing of global variables to transfer individual line
values of a table to a different control recipe. You add the <LS>_1</>,
<LS>_2 </>, <LS>_3</> and so on behind the global variable &V1& for
each table line.
Example:
&V1&_1: Variable for the value in line 1
&V1&_2: Variable for the value in line 2
&V1&_3: Variable for the value in line 3
Each variable must be declared separately.
Generate the control recipe again.
Resend the control recipe.
Extracto de mensaje de error del sistema SAP. Copyright SAP SE.
CPOC138
- Declaración incorrecta de las variables globales &1 ?Get instant SAP help. Start your 7-day free trial now.
CPOC137
Sólo la firma final puede realizarse de forma asincrónica
¿Qué causa este problema? You have set the <DS:DE.CO_SIGNASYN>Asyn. signature process</> indicator in the process instruction. This ind...
CPOC136
Clase característica &1 no es numérica
¿Qué causa este problema? If you have defined a constant default value as a numeric value (PPPI_DEFAULT_VALUE) when defining entries, the data type...
CPOC139
Característica &1 no permitida en Manufacturing Cockpits
¿Qué causa este problema? Unlike in PI sheets, the following functions are not supported in the process manufacturing cockpit: The definition of gl...
CPOC140
Utilizar otra variable para el parámetro &2
¿Qué causa este problema? A dynamic function call is defined in the process instruction. Variable &V1& was passed to parameter &V1&...