Black Friday is ending this Friday! 40% off with coupon CYBER40 - Sign up here →
Message type: E = Error
Message class: CPOC - PP-PI-PMA: Process Operator Cockpit Messages
Message number: 106
Message text: Indique fórmula de cálculo
Characteristic PPPI_CALCULATED_VALUE defines the value to be
calculated. You must define the relevant calculation formula
immediately after this characteristic using characteristic
PPPI_CALCULATION_FORMULA.
The calculation formula is, however, not defined at this point in the
process instruction.
El sistema emite un mensaje de error y no le permitirá continuar con esta transacción hasta que se resuelva el error.
RESET N1
Assign characteristic PPPI_CALCULATION_FORMULA to the process
instruction immediately after characteristic PPPI_CALCULATED_VALUE.
Assign the formula you want to use to this characteristic.
Extracto de mensaje de error del sistema SAP. Copyright SAP SE.
Get instant SAP help. Sign up for our Free Essentials Plan.
CPOC105 Delante de PPPI_EXTERNAL_VALUE falta car.PPPI_DEFAULT_VARIABLE
¿Qué causa este problema? Characteristic PPPI_EXTERNAL_VALUE determines that a variable is to be used to assign a value to the message characterist...
CPOC104 Característica &1 no prevista en esta posición
¿Qué causa este problema? You cannot use characteristic &V1& because its position does not comply with the defined characteristic sequence ...
CPOC107 Asigne un valor al parámetro &1
¿Qué causa este problema? The following characteristics are used to assign the interface parameters of the function module to be called to the proc...
CPOC108 La variable &1 ya se ha utilizado en otra posición
¿Qué causa este problema? In the process instruction, you have used variable &V1& that Has already been defined at a different position in ...
Haga clic en este enlace para buscar todos los mensajes de SAP.