How To Fix BRAIN313 - La característica &1 tiene para el InfoSitio &2 un problema CMP


SAP Error Message - Details

  • Message type: E = Error

  • Message class: BRAIN -

  • Message number: 313

  • Message text: La característica &1 tiene para el InfoSitio &2 un problema CMP

  • Show details Hide details
  • ¿Qué causa este problema?

    Characteristic &V1& of CompositeProvider/MultiProvider is not provided
    with data from the included InfoProvider &V2&. This means that it is not
    identified. &V1& is compounded to &V4& however, and &V4& is identified
    for InfoProvider &V2& with characteristic &V3&.
    There is a compounding or CMP problem with &V1& in the
    CompositeProvider/MultiProvider for InfoProvider &V2&.
    During query execution, is very complicated to process characteristics
    with CMP problems and can result in long runtimes:

    El sistema emite un mensaje de error y no le permitirá continuar con esta transacción hasta que se resuelva el error.

    BW in general uses artificial surrogate identifiers (SIDs) as keys to
    link characteristic values to any kind of fact or master data at query
    runtime. These SIDs are 4-byte integer values. They are also used as
    keys for compounded characteristics. In the compounded case, a single
    SID replaces a compounded key.
    Example 1: simple characteristic country
    <EX> Country SID</>
    <EX> initial 0</>
    <EX> DE 1</>
    <EX> US 2</>
    <EX>Example 2: compounded characteristic region</>
    <EX> Country Region SID</>
    <EX> initial initial 0</>
    <EX> DE initial 1</>
    <EX> DE BY,,,,2</>
    <EX> DE BW,,,,3</>
    With a CMP problem, the analytic engine cannot use SIDs for
    characteristics of this kind - or at least not for the InfoProvider -
    because the initial SID = 0 for &V1& is not the same as the initial
    compound key for &V4& &V1& (if actual values are posted in &V2& for
    &V4&).
    Hierarchies for &V1& must therefore often be read at leaf level. Also,
    it is not possible to use hierarchy aggregates for &V1& or for the
    remaining InfoProviders.

    Respuesta del sistema

    The system tries to avoid negative impacts on performance wherever
    possible. Unfortunately, performance issues cannot be avoided in some
    cases if you want to display the correct results.
    Also pushdown of OLAP functionality into SAP HANA/BWA is limited or even
    completely prevented if CMP problems occur.

    ¿Cómo arreglar este error?

    SAP strongly advises not to use CompositeProviders or MultiProviders
    with CMP problems. There are 3 ways to overcome CMP problems:
    Add the characteristic &V1& to all InfoProviders within the
    CompositeProvider or MultiProvider
    Add characteristic &V1& or a characteristic compounded to &V4& that can
    be identified using &V1& to InfoProvider &V2&. The value for &V1& can
    always be initial in &V2&.
    Hide the affected characteristic &V1& in the CompositeProvider or
    MultiProvider
    If it is not convenient to have characteristic &V1& in InfoProvider &V2&
    , you can hide it by setting the InfoProvider-specific properties,
    selection = '4' and CHANAV = '2', for &V1& in InfoProvider &V2&.
    CHANAV cannot be changed directly in the provider-specific properties.
    CHANAV must be changed using transaction SE16 in table RSDICHAPRO.
    To change this property for the relevant characteristic, fill the
    following fields in transaction SE16:
    INFOCUBE: &V2&
    OBJVERS: M
    CHANM: &V1& (enter the technical name only)
    Set CHANAV = '2' for the selected record. If the InfoProvider is changed
    and reactivated in InfoProvider maintenance after this change is
    performed, the CHANAV change also becomes effective.
    This means that &V1& remains hidden in InfoProvider &V2&, which means
    that &V1& is not available in Query Designer. InfoProvider &V2& is not
    actually changed, but the CMP problem for &V1& in the
    CompositeProvider/MultiProvider is resolved. Note that warning message
    Brain 263 will be displayed when the CompositeProvider/MultiProvider is
    checked, but you can ignore this warning.
    Set the compounding parent characteristic &V4& as a constant in the
    affected InfoProvider &V2&
    If all data records from &V2& for &V4& have the same value, you can set
    &V4& for InfoProvider &V2& as a constant value (see SAP Note 1038604).
    The system can then use an SID again for &V1&, and the CMP problem will
    no longer be an issue.

    Procedimiento para Administradoras de Sistemas


    Extracto de mensaje de error del sistema SAP. Copyright SAP SE.


Smart SAP Assistant

  • ¿Cuál es la causa y la solución del error de SAP BRAIN313 - La característica &1 tiene para el InfoSitio &2 un problema CMP ?




    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.


Mensajes de error de SAP relacionados

Haga clic en los enlaces a continuación para ver los siguientes mensajes relacionados:

Haga clic en este enlace para buscar todos los mensajes de SAP.


Rating
ERPlingo's SAP support assistant is amazing. Saves me countless hours trying to solve complex SAP issues myself. It's a real game changer!
Rate 1
Thomas Michael
SAP Consultant, Author & Speaker