Do you have any question about this error?
Message type: E = Error
Message class: BIL - General billing
Message number: 108
Message text: El factor de gas &1 no puede determinarse unívocamente
During <ZH>determination of the gas factor</>, the following error
occurred: It was not possible to determine the gas factor <ZH>uniquely
</>.
To avoid inconsistencies, the system terminates processing.
Check whether you have entered <ZH>all required</> meter readings using
the <ZH>correct meter reading category</> for a device. See the
following notes. If you are unable to solve the problem after reading
these, please contact SAP.
<ZH><ZU><ZK>Comments</></></>
<ZK>For <DS:DE.E_QD_PROC>quantity determination procedure</> 03 -
Quantity Determination During Meter Reading, it is very important that a
<ZH>unique</> </><ZH><ZK>gas factor can be determined</></> for the
<ZK>period between a meter reading and the previous meter reading.</>
<ZK>This includes not changing the </><ZH><ZK>gas procedure</></><ZK>
during this period unless an additional </><ZH><ZK>actual</></><ZK>meter
reading is available for the proration time ( activity day- 1 ).</>
<ZK>The gas procedure implemented must also be set up so that it does
not produce historical factors during this period. This means that you
usually require gas procedures whose components are calculated by </>
<ZH><ZK>averaging</></><ZK> or by using</><ZH><ZK>constant factors</></>
<ZK>.</>
<ZK>If you change the fields </><ZH><ZK>Gas Procedure,</></><ZK> </><ZH>
<ZK>Fixed Temperature</></><ZK>and </><ZH><ZK>Volume Correction Factor
</></><ZK> ( from register), which you change using the transactions
<ZH>EG70</> or <ZH>EC30</>, you also require </><ZH><ZK>actual</></><ZK>
meter readings.</>
<ZK>For additional notes about using the correct meter reading type, see
the long text for the following message <DS:NA.EE_QD106>EE_QD 106</></>
El sistema emite un mensaje de error y no le permitirá continuar con esta transacción hasta que se resuelva el error.
Extracto de mensaje de error del sistema SAP. Copyright SAP SE.
BIL108
- El factor de gas &1 no puede determinarse unívocamente ?Get instant SAP help. Start your 7-day free trial now.
BIL107
Conversión a dimensión interm.imposible con proc.p.determ.cantidad &1
¿Qué causa este problema? You are using a variant program to determine a quantity with an interim dimension. However, this is not possilbe with the...
BIL106
Ctrl.períodos dinámico no permitido en proceso p.determinar cantidad &1
¿Qué causa este problema? The rate category &v2& uses dynamic period control (DPC). The installation contains devices with quantity determi...
BIL109
Indique una clase de tarifa que presente la misma clase de redondeo
¿Qué causa este problema? Different rounding types were found for the register in installations &v1& and &v2& for the period from &...
BIL110
Indique un esquema con un programa de cálculo condicional
¿Qué causa este problema? You have specified in rate category &v2& that a conditional billing program can be executed. However, the schema ...
Haga clic en este enlace para buscar todos los mensajes de SAP.