How To Fix AJ346 - Desbordamiento no válido en aparato &1, numer.&2, de fecha &3 a fecha &4


SAP Error Message - Details

  • Message type: E = Error

  • Message class: AJ - Billing program

  • Message number: 346

  • Message text: Desbordamiento no válido en aparato &1, numer.&2, de fecha &3 a fecha &4

  • Show details Hide details
  • ¿Qué causa este problema?

    For device &v1&, <ZK>register</> &v2&, the rounded meter reading for
    date &v3& is greater than the rounded meter reading for date &v4&.
    However, the amount of the difference is less than 1.
    The error may have caused by an artificial meter overflow resulting from
    the rounding. This problem may occur, for example, if the meter reading
    rounding changed due to a rate change.

    Respuesta del sistema

    This error can occur in billing in two processes:
    During rounding of the actual meter reading results to the meter reading
    rounding
    During rounding of the meter reading results generated artificially as a
    result of proration
    In this case, the specified to-date &v4& is the proration date up to
    which a result was calculated. This result is rounded and compared to
    the result taken or calculated earlier. An artificial overflow was
    determined in this process.

    ¿Cómo puede suceder esto?

    You have recorded three meter readings. Two of them were read with three
    decimal places. After the second result (10.957) was entered, the rate
    changed, which resulted in a change in the meter reading rounding from
    three to no decimal places (DP).
    |-------------------|
    0 3 DP 10.123
    |------------------|
    10.123 3 DP 10.957
    |------------------|
    10.957 0 DP 20
    Rounding results in the following readings:
    0 10.123 10 20
    10.957 was rounded down to 10 (minimum of meter reading roundings 3 DP
    and 0 DP). However, the reading is then lower than the previous reading
    (10.123). As a result of the rounding, an artificial meter reading
    overflow was generated.
    The system cannot continue processing of the billing order.

    Respuesta del sistema

    El sistema emite un mensaje de error y no le permitirá continuar con esta transacción hasta que se resuelva el error.

    ¿Cómo arreglar este error?

    Change the meter reading results in a way that rounding cannot result in
    a meter overflow.
    If the error resulted from artificially generated proration readings,
    you can enter an estimated result for proration date &v4& or you can
    change the results before and after the proration date in such a way
    that the error does not occur (for example, you can manually round the
    results down to zero decimal places).
    Note
    In some cases, the error can also occur in other situations, for
    example, if an estimated meter reading exists in the database and there
    is a meter overflow as a result of the next actual meter reading.
    If this occurs, you can also use the procedure described above by adding
    a new estimated meter reading or by changing the existing one.
    We recommend that you also do this to replace obsolete estimatons with
    more exact new estimations (for example, interpolation instead of
    extrapolation).

    Procedimiento para Administradoras de Sistemas


    Extracto de mensaje de error del sistema SAP. Copyright SAP SE.


Smart SAP Assistant

  • ¿Cuál es la causa y la solución del error de SAP AJ346 - Desbordamiento no válido en aparato &1, numer.&2, de fecha &3 a fecha &4 ?




    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.


Mensajes de error de SAP relacionados

Haga clic en los enlaces a continuación para ver los siguientes mensajes relacionados:

Haga clic en este enlace para buscar todos los mensajes de SAP.


Rating
The AI Support Assistant is great. It provides comprehensive assistance even on the most difficult issues. I highly recommend this service.
Rate 1
John Jordan
SAP Consultant & Author