Do you have any question about this error?
Message type: E = Error
Message class: WRF_WLAY - Messages in Layout Environment in Fashion Solution
Message number: 325
Message text: Capacity check not possible for articles of fixture &1
The system cannot carry out the capacity check because the units of
dimension maintained for the materials do not match the unit of measure
for the fixture capacity.
Materials are assigned to fixtures with the dimensions "length" or
"volume", and the units of measure of the materials and the fixtures to
which they are assigned, are different or do not exist. The following
conditions:
All materials and fixtures must be assigned units of dimension
(materials), or units of measure (fixtures).
All materials assigned to a fixture must have the same unit of
dimension.
Materials and the fixtures to which they are assigned must share the
same unit.
The system does not check the fixture capacity.
Check that the materials and the fixtures to which they are assigned
have the same units of measure or implement the BAdI WRF_WLAY_CAPA_CHECK
to convert the unit of dimension to a different unit of dimension:
Use method CHANGE_FIX_LENGTH_CHECK if the dimension of the fixture is
"length".
Use method CHANGE_FIX_VOLUME_CHECK if the dimension of the fixture is
"volume".
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
WRF_WLAY325
- Capacity check not possible for articles of fixture &1 ?The SAP error message WRF_WLAY325 indicates that a capacity check cannot be performed for articles associated with a specific fixture. This error typically arises in the context of warehouse management or logistics when the system is unable to determine the available capacity for a particular storage location or fixture.
Causes:
- Missing or Incorrect Configuration: The fixture or storage location may not be properly configured in the system, leading to an inability to perform capacity checks.
- Data Inconsistencies: There may be inconsistencies in the master data for the articles or fixtures, such as incorrect unit of measure or capacity settings.
- Capacity Limits Exceeded: The fixture may have reached its maximum capacity, and the system is unable to allocate additional items.
- System Settings: The system settings for capacity checks may not be correctly defined, leading to failures in the check process.
Solutions:
- Check Fixture Configuration: Verify that the fixture is correctly configured in the system. Ensure that all relevant parameters, such as capacity and dimensions, are accurately defined.
- Review Article Master Data: Check the master data for the articles involved. Ensure that the unit of measure, weight, and volume are correctly set up.
- Capacity Management: Review the capacity settings for the fixture. If the fixture is full, consider redistributing items or increasing the capacity if possible.
- System Settings: Review the settings related to capacity checks in the SAP system. Ensure that the necessary configurations are in place to allow for capacity checks.
- Consult Documentation: Refer to SAP documentation or help resources for specific guidance on capacity checks and fixture management.
Related Information:
MM03
(Display Material), LS03N
(Display Storage Location), or LX02
(Inventory Management) to check the relevant data.By following these steps, you should be able to identify the root cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
WRF_WLAY323
Article &1, layt mod. &2, vers. &3, No 'Optimal Shelf Qty' defined
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
WRF_WLAY322
Transfer of layt mod. &1, version &2 in status 'planned' is not permitted
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
WRF_WLAY330
Valid from date of new version changed to the following workday
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
WRF_WLAY335
Label type &1 does not exist in the system
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.