Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: WA - Messages from Workflow Event Manager
Message number: 633
Message text: Type linkage between & & and &: Activation not possible
The specified type linkage between object type and event and the
specified receiver type cannot be activated.
The action was terminated, the entry is not changed.
Check whether the specified linkage exists.
INCLUDE NA_WF-ADMINISTRATOR OBJECT DOKU ID TX
Error message extract from SAP system. Copyright SAP SE.
WA633
- Type linkage between & & and &: Activation not possible ?Certainly! Here's a detailed explanation for the SAP error message:
SAP Error Message:
WA633 Type linkage between & & and &: Activation not possible
Meaning / Cause:
This error occurs during the activation of an ABAP Dictionary object (such as a table, structure, or data element) when there is an inconsistency or mismatch in the type linkage between related data types or structures.
Type linkage in SAP means that one data type is linked or dependent on another. For example, a table field might be linked to a data element, or a structure might be linked to another structure or data element. If the system detects that the linkage between these types is inconsistent or invalid, it prevents activation to avoid runtime errors or data inconsistencies.
Common causes include:
Check the Type Linkage:
&
will be replaced by actual object names in the real message).Activate Dependent Objects First:
Check for Circular References:
Use the Where-Used List:
Transport Consistency:
Adjust or Recreate the Object:
Aspect | Description |
---|---|
Cause | Inconsistent or invalid type linkage between related data types or structures. |
Effect | Activation of the object is blocked to prevent runtime errors. |
Solution | Check and correct type definitions, activate dependent objects first, remove circular refs. |
Tools | SE11 (Data Dictionary), Where-Used List, Transport Organizer. |
If you provide the actual object names from the error message, I can help you with more specific guidance.
Get instant SAP help. Sign up for our Free Essentials Plan.
WA632
Type linkage between & & and &: Deactivation not possible
What causes this issue? The specified type linkage between object type and event and the specified receiver type cannot be deactivated.System Respons...
WA631
Type linkage between & & and &: Deletion not possible
What causes this issue? The specified type linkage between object type and event and the specified receiver type cannot be deleted.System Response T...
WA634
Type linkage between & & and &: Insertion not possible
What causes this issue? The specified type linkage between object type and event and the specified receiver type cannot be entered.System Response T...
WA635
Type linkage betw. & & and &: Not possible to change receiver funct.mod.&
What causes this issue? The function module which is to be called so that the event can be received by the receiver type ( <DS:GLOS.3526B12EAFAB52...
Click on this link to search all SAP messages.