How To Fix VT662 - Internal error &2 when saving access sequence &1 (see long text)


VT662 - Overview

  • Message type: E = Error

  • Message class: VT - Vertriebstabellen

  • Message number: 662

  • Message text: Internal error &2 when saving access sequence &1 (see long text)

  • Show details Hide details
  • What causes this issue?

    An internal error occurred when saving access sequence &V1&, access &V3&
    that cannot be corrected in the processing dialog.
    <ZH>Internal error 1:</>
    There is more than one entry for the exact same access number in the
    access table (T682I).
    <ZH>Internal error 2:</>
    There is an entry in the field assignment table (T682Z) for which there
    is no corresponding access (T682I).
    <ZH>Internal error 3:</>
    There is an entry in the access table (T682I) for which there is no
    corresponding access sequence (T682).

    System Response

    The changes are not saved.

    How to fix this error?

    Restart the transaction.

    Procedure for System Administrators

    The system issues an error message and will not allow you to continue with this transaction until the error is resolved.


    Error message extract from SAP system. Copyright SAP SE.


Smart SAP Assistant

  • What is the cause and solution for SAP error message VT662 - Internal error &2 when saving access sequence &1 (see long text) ?
    The SAP error message VT662 indicates an internal error that occurs when saving an access sequence in the SAP system. This error can be caused by various factors, including inconsistencies in the configuration, issues with the database, or problems with the transport layer.
    Possible Causes:
    
    Database Issues: There may be inconsistencies or corruption in the database tables related to the access sequence.
    Configuration Errors: Incorrect or incomplete configuration settings in the access sequence or related objects.
    Transport Layer Problems: Issues with the transport layer, such as missing transport requests or problems with the transport directory.
    Authorization Issues: Lack of necessary authorizations to save changes to the access sequence.
    System Bugs: There may be bugs in the SAP system that lead to this internal error.
    
    Solutions:
    
    Check Configuration: Review the access sequence configuration for any inconsistencies or missing entries. Ensure that all required fields are filled out correctly.
    Database Consistency Check: Run database consistency checks to identify and resolve any

    Already have an account? Login here!




Instant HelpGet instant SAP help. Sign up for our Free Essentials Plan.


Related SAP Error Messages

Click the links below to see the following related messages:

Click on this link to search all SAP messages.


Rating
The AI Support Assistant is great. It provides comprehensive assistance even on the most difficult issues. I highly recommend this service.
Rate 1
John Jordan
SAP Consultant & Author