Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now

Close

How To Fix VHUMISC012 - PI determination w/o conditions - Customizing for PI determ. incomplete


SAP Error Message - Details

  • Message type: E = Error

  • Message class: VHUMISC - Messages for General Function Modules for Packing Logistics

  • Message number: 012

  • Message text: PI determination w/o conditions - Customizing for PI determ. incomplete

  • Show details Hide details


  • Self-Explanatory Message

    Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.

    To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.

    Unfortunately, there isn't any extra information in this error notice.



    What else can you do?

    First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).

    Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.

    You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.


Smart SAP Assistant

  • What is the cause and solution for SAP error message VHUMISC012 - PI determination w/o conditions - Customizing for PI determ. incomplete ?

    The SAP error message VHUMISC012 indicates that there is an issue with the Product Interchangeability (PI) determination process in SAP. Specifically, it suggests that the system is attempting to perform PI determination without the necessary conditions being set up in the customizing settings. Here’s a breakdown of the cause, potential solutions, and related information:

    Cause:

    1. Incomplete Customizing: The error typically arises when the customizing settings for Product Interchangeability are not fully configured. This could mean that the necessary condition records for PI determination are missing or not properly defined.
    2. Missing Condition Records: The system may not find any valid condition records that match the criteria for PI determination, leading to this error.
    3. Incorrect Configuration: There may be incorrect or incomplete configuration in the relevant customizing settings for PI determination.

    Solution:

    1. Check Customizing Settings:

      • Navigate to the customizing settings for Product Interchangeability in SAP. This can usually be found under:
        • SPRO ? Logistics ? Logistics Execution ? Product Interchangeability ? Define Conditions for Product Interchangeability.
      • Ensure that the necessary condition types and records are defined correctly.
    2. Create or Update Condition Records:

      • If condition records are missing, create them using transaction VK11 (Create Condition) or VK12 (Change Condition) for the relevant condition type.
      • Ensure that the records are valid for the relevant materials and that the validity dates are set correctly.
    3. Check PI Determination Procedure:

      • Verify that the PI determination procedure is correctly assigned to the relevant materials or product groups.
      • Ensure that the procedure is active and that all necessary settings are in place.
    4. Testing:

      • After making the necessary changes, test the PI determination process again to ensure that the error is resolved.
    5. Consult Documentation:

      • Refer to SAP documentation or help files for detailed guidance on setting up Product Interchangeability and troubleshooting related issues.

    Related Information:

    • Transaction Codes: Familiarize yourself with relevant transaction codes such as VK11, VK12, VK13 (Display Condition), and SPRO for customizing.
    • SAP Notes: Check for any relevant SAP Notes that may address specific issues related to PI determination or provide updates and patches.
    • User Forums and Communities: Engage with SAP community forums or user groups for additional insights and shared experiences regarding similar issues.

    By following these steps, you should be able to resolve the VHUMISC012 error and ensure that the PI determination process functions correctly in your SAP system.

    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Sign up for our Free Essentials Plan.


Related SAP Error Messages

Click the links below to see the following related messages:

Click on this link to search all SAP messages.


Rating
ERPlingo simplifies finding the accurate answers to SAP message errors. I now use every week. A must have tool for anyone working with SAP! Highly recommended!
Rate 1
Kent Bettisworth
Executive SAP Consultant