Message type: E = Error
Message class: UPWB - Messages for Development Class UPWB
Message number: 125
Message text: Access to BSP application &1 not allowed
You attempted to delete Web interface &V1&. The BSP application
generated on the basis of the Web interface is also deleted
simulataneously here. You do not have the necessary authorization for
this.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Check your current authorizations, or inform the system administrator.
Error message extract from SAP system. Copyright SAP SE.
UPWB125
- Access to BSP application &1 not allowed ?The SAP error message UPWB125, which states "Access to BSP application &1 not allowed," typically occurs when a user attempts to access a Business Server Page (BSP) application for which they do not have the necessary authorizations. This can happen in various scenarios, such as when trying to access a specific BSP application or when the application is not properly configured.
Cause:
- Authorization Issues: The user does not have the required authorizations to access the BSP application. This could be due to missing roles or authorizations in the user's profile.
- BSP Application Configuration: The BSP application may not be correctly configured or may not be activated in the system.
- System Settings: There may be restrictions set at the system level that prevent access to certain BSP applications.
Solution:
Check User Authorizations:
- Use transaction code
SU53
immediately after encountering the error to check for missing authorizations.- Review the user's roles and profiles in transaction
PFCG
to ensure that the necessary authorizations for the BSP application are included.BSP Application Activation:
- Ensure that the BSP application is activated. You can check this in transaction
SE80
orSE41
by navigating to the BSP application and verifying its status.- If the application is not activated, you may need to activate it using transaction
SE80
or by using the appropriate activation method.Check System Settings:
- Review any system-wide settings or restrictions that may be in place. This could include settings in transaction
SICF
(Internet Communication Framework) where the BSP application is defined.- Ensure that the service for the BSP application is active and that there are no access restrictions.
Consult Documentation:
- Refer to SAP documentation or notes related to the specific BSP application for any additional configuration or authorization requirements.
Contact SAP Support:
- If the issue persists after checking the above points, consider reaching out to SAP support for further assistance, especially if it involves a custom BSP application.
Related Information:
SU53
: Display Authorization CheckPFCG
: Role MaintenanceSE80
: Object NavigatorSICF
: Maintain ServicesBy following these steps, you should be able to diagnose and resolve the UPWB125 error effectively.
Get instant SAP help. Sign up for our Free Essentials Plan.
UPWB124
Error when copying the MIME object &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
UPWB123
Define name for Web interface or generate BSP application (see long text)
What causes this issue? You selected a function, which the system can only execute when the name of the Web interface is known. However, this is not ...
UPWB126
An error occurred when deleting the BSP application
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
UPWB127
Error when reading the master data of Web interface &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.