Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now

Close

How To Fix UPO_MIG171 - No measurement master found for the MP


SAP Error Message - Details

  • Message type: E = Error

  • Message class: UPO_MIG - Message Class for PRA->UOM Migration

  • Message number: 171

  • Message text: No measurement master found for the MP

  • Show details Hide details


  • Self-Explanatory Message

    Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.

    To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.

    Unfortunately, there isn't any extra information in this error notice.



    What else can you do?

    First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).

    Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.

    You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.


Smart SAP Assistant

  • What is the cause and solution for SAP error message UPO_MIG171 - No measurement master found for the MP ?

    The SAP error message UPO_MIG171 indicates that there is no measurement master record found for the specified measurement point (MP). This error typically occurs in the context of SAP's Utilities or Plant Maintenance modules, where measurement points are used to track consumption or readings from various devices.

    Cause:

    1. Missing Measurement Master Record: The most common cause is that the measurement point you are trying to access does not have an associated measurement master record in the system.
    2. Incorrect Configuration: The measurement point may not be properly configured or may have been deleted or not created at all.
    3. Data Migration Issues: If you are migrating data from another system or performing a system upgrade, there may be issues with the data transfer that resulted in missing records.
    4. Authorization Issues: Sometimes, the user may not have the necessary authorizations to view or access the measurement master records.

    Solution:

    1. Check Measurement Point Configuration:

      • Go to the transaction code IK01 (Create Measurement Point) or IK02 (Change Measurement Point) and verify if the measurement point exists and is correctly configured.
      • Ensure that the measurement point is assigned to the correct measuring point type and that all required fields are filled out.
    2. Create or Update Measurement Master Record:

      • If the measurement master record is missing, you can create it using transaction code IK01 (Create Measurement Document) or IK02 (Change Measurement Document).
      • Ensure that the measurement point is linked to the correct measuring point and that all necessary data is entered.
    3. Data Migration Check:

      • If this error occurred after a data migration, review the migration logs to identify any issues that may have occurred during the transfer of measurement point data.
      • Ensure that all relevant data was migrated correctly and that there are no discrepancies.
    4. Authorization Check:

      • Verify that the user has the necessary authorizations to access the measurement master records. This can be done by checking the user roles and authorizations in the SAP system.
    5. Consult Documentation:

      • Refer to SAP documentation or help resources for additional guidance on measurement points and master records.

    Related Information:

    • Transaction Codes: Familiarize yourself with relevant transaction codes such as IK01, IK02, IK03 (Display Measurement Point), and IK17 (Display Measurement Document).
    • SAP Notes: Check for any relevant SAP Notes that may address this specific error or provide additional troubleshooting steps.
    • Support: If the issue persists after following the above steps, consider reaching out to your SAP support team or consulting with SAP support for further assistance.

    By following these steps, you should be able to resolve the UPO_MIG171 error and ensure that the measurement master records are correctly set up in your SAP system.

    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Sign up for our Free Essentials Plan.