Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: UCF6 - Messages for Consolidation of Investments
Message number: 711
Message text: Investee unit &1 is a parent unit in sender group &2
<DS:GLOS.3526B7CEAFAB52B9E10000009B38F974>Investee unit</> &V1& is
flagged as a parent unit in sender consolidation group &V2&. This
prevents this consolidation group from providing sender data for
<DS:GLOS.5A350989A637D511AE740800062AFB0F>organizational changes</> to
the investee unit.
This would cause incomplete postings in the receiver consolidation
groups that are assigned to sender group &V2& and acquire investee unit
&V1& as defined in the organizational changes.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
UCF6711
- Investee unit &1 is a parent unit in sender group &2 ?The SAP error message UCF6711 indicates that there is an issue with the configuration of the sender group in the context of the Universal Financial Consolidation (UFC) module. Specifically, it means that the investee unit (the unit you are trying to process) is a parent unit in the specified sender group, which can lead to issues in the consolidation process.
Cause:
The error occurs when you attempt to perform a consolidation operation on an investee unit that is designated as a parent unit in the sender group. This situation can arise due to:
- Incorrect Hierarchy Configuration: The unit you are trying to consolidate is set up as a parent in the organizational structure, which conflicts with the consolidation process.
- Data Entry Errors: There may be incorrect data entries or configurations in the sender group or the investee unit.
- Circular References: The configuration may inadvertently create circular references in the hierarchy.
Solution:
To resolve the UCF6711 error, you can take the following steps:
Check the Hierarchy: Review the organizational structure and ensure that the investee unit is correctly defined. If it is a parent unit, it should not be included in the consolidation as an investee.
Adjust Sender Group Configuration: If the investee unit is indeed a parent unit, you may need to adjust the sender group configuration to exclude it from the consolidation process.
Review Data Entries: Ensure that all data entries related to the investee unit and sender group are correct and consistent with the intended consolidation structure.
Consult Documentation: Refer to the SAP documentation for Universal Financial Consolidation for specific guidelines on configuring sender groups and handling parent and investee units.
Seek Help from SAP Support: If the issue persists after checking the configuration and data, consider reaching out to SAP support for further assistance.
Related Information:
By following these steps, you should be able to identify the root cause of the UCF6711 error and implement the necessary changes to resolve it.
Get instant SAP help. Sign up for our Free Essentials Plan.
UCF6710
Org. change for first consolidation/divestiture at period end/start
What causes this issue? The organizational change-related activity &V1& with activity number &V2& involves a higher-level unit that i...
UCF6709
Org. change for first consolidation/divestiture at period end/start
What causes this issue? The organizational change-related activity &V1& with activity number &V2& has been recorded even though the i...
UCF6712
Consolidation of investments in not active in consolidation area &1
What causes this issue? The consolidation of investments indicator is not selected in the settings for <DS:GLOS.D5692F24DA2CD511BCBF0800060D9C68&g...
UCF6713
Sum of direct shares in investee unit &1 equals &2
What causes this issue? The sum of the direct shares of investee unit &V1& is &V2& percent. This figure must be between zero and one ...
Click on this link to search all SAP messages.