Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now

Close

How To Fix UA_FORMULA039 - Target quantity unit of measure could not be determined


SAP Error Message - Details

  • Message type: E = Error

  • Message class: UA_FORMULA - Formula Editor Messages

  • Message number: 039

  • Message text: Target quantity unit of measure could not be determined

  • Show details Hide details


  • Self-Explanatory Message

    Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.

    To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.

    Unfortunately, there isn't any extra information in this error notice.



    What else can you do?

    First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).

    Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.

    You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.


Smart SAP Assistant

  • What is the cause and solution for SAP error message UA_FORMULA039 - Target quantity unit of measure could not be determined ?

    The SAP error message UA_FORMULA039, which states "Target quantity unit of measure could not be determined," typically occurs in the context of material management or production planning when the system is unable to determine the appropriate unit of measure for a target quantity in a formula or recipe.

    Causes:

    1. Missing Unit of Measure Configuration: The target quantity may not have a defined unit of measure in the material master or in the recipe/formula.
    2. Incorrect Material Master Data: The material master may not have the necessary data set up correctly, such as the base unit of measure or alternative units of measure.
    3. Inconsistent Data: There may be inconsistencies in the data between the material master and the recipe/formula, such as different units of measure being used.
    4. Missing Conversion Factors: If the system needs to convert between different units of measure, missing conversion factors can lead to this error.
    5. Incorrectly Defined Recipes/Formulas: The recipe or formula may not be set up correctly, leading to issues in determining the target quantity's unit of measure.

    Solutions:

    1. Check Material Master Data:

      • Go to the material master (transaction code MM03) and verify that the unit of measure is correctly defined.
      • Ensure that the base unit of measure and any alternative units of measure are set up properly.
    2. Review Recipe/Formula:

      • Check the recipe or formula (transaction code C201 or C202) to ensure that the target quantity and its unit of measure are correctly defined.
      • Make sure that the target quantity is linked to the correct material.
    3. Define Conversion Factors:

      • If applicable, ensure that conversion factors between different units of measure are defined in the material master.
    4. Check for Inconsistencies:

      • Look for any inconsistencies between the material master and the recipe/formula. Ensure that the units of measure match and are compatible.
    5. Consult Documentation:

      • Review SAP documentation or help resources for specific guidance on the error message and related configuration settings.
    6. Contact SAP Support:

      • If the issue persists after checking the above points, consider reaching out to SAP support for further assistance.

    Related Information:

    • Transaction Codes: MM03 (Display Material), C201 (Create Recipe), C202 (Change Recipe).
    • Unit of Measure Configuration: This can be found in the material master under the "Basic Data" view and "Purchasing" view.
    • SAP Notes: Check for any relevant SAP Notes that may address this specific error or provide additional troubleshooting steps.

    By following these steps, you should be able to identify and resolve the issue causing the UA_FORMULA039 error in SAP.

    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Sign up for our Free Essentials Plan.