Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: TPDA - Debugger
Message number: 886
Message text: Watchpoint cannot be created (area of validity varies)
The watchpoint variable and the variables used in the watchpoint
condition must have the same validity area.
For example, it is not possible to set a watchpoint on a global variable
(SY-SUBRC) and refer to a local variable in the condition.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Use variables with the same validity area for a watchpoint.
Error message extract from SAP system. Copyright SAP SE.
TPDA886
- Watchpoint cannot be created (area of validity varies) ?The SAP error message TPDA886, which states "Watchpoint cannot be created (area of validity varies)," typically occurs in the context of debugging within the SAP environment. This error is related to the creation of watchpoints, which are used to monitor the value of variables during program execution.
Cause:
The error can arise due to several reasons:
- Scope Issues: The variable you are trying to set a watchpoint on may not be in the current scope or context. This can happen if the variable is local to a function or method that is not currently being executed.
- Invalid Variable: The variable may not be valid at the point where you are trying to create the watchpoint. This can occur if the variable has gone out of scope or has not been initialized.
- Debugging Session State: The debugging session may not be in a state that allows for the creation of watchpoints, such as being paused or not at a breakpoint.
- System Limitations: There may be limitations or restrictions in the SAP system regarding the number of watchpoints that can be created or the types of variables that can be monitored.
Solution:
To resolve the TPDA886 error, you can try the following steps:
- Check Variable Scope: Ensure that the variable you are trying to monitor is in the correct scope. You may need to set the watchpoint at a different point in the code where the variable is valid.
- Reinitialize the Debugging Session: Restart the debugging session and ensure that you are at a valid breakpoint before attempting to create the watchpoint again.
- Use Global Variables: If possible, use global variables or ensure that the variable is accessible in the context where you are trying to set the watchpoint.
- Limit Watchpoints: If you have reached the maximum number of watchpoints allowed, consider removing some existing watchpoints before adding new ones.
- Check for Updates: Ensure that your SAP system is up to date, as there may be patches or updates that address this issue.
Related Information:
If the problem persists after trying these solutions, consider reaching out to your SAP Basis or development team for further assistance, as they may have more insights into the specific configuration and limitations of your SAP environment.
Get instant SAP help. Sign up for our Free Essentials Plan.
TPDA885
There are no options
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
TPDA882
Operation terminated because the stack was not reset
What causes this issue? The current stack pointer was not at the end of the stack but in the middle. However, for the operation the stack pointer mus...
TPDA887
Watchpoint cannot be created (area of validity)
What causes this issue? The watchpoint variable, or a variable of the condition, has a validity area that is not supported. For example, it is not po...
TPDA888
Cannot create watchpoint; error in condition
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.