Message text: RFC error. System: & Table: & RC: &
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
TA231
- RFC error. System: & Table: & RC: & ?The SAP error message TA231 typically indicates an RFC (Remote Function Call) error. This error can occur for various reasons when trying to establish a connection between SAP systems or when calling a remote function module. Here’s a breakdown of the potential causes, solutions, and related information for this error:
Causes of TA231 RFC Error
Network Issues: There may be network connectivity problems between the SAP systems involved in the RFC call.
Configuration Issues: The RFC destination may not be configured correctly in the SAP system. This includes incorrect settings in transaction
SM59
.Authorization Issues: The user credentials used for the RFC call may not have the necessary authorizations to execute the function module.
System Availability: The target system may be down or not reachable due to maintenance or other issues.
Incorrect Function Module: The function module being called may not exist in the target system or may have been changed.
Timeouts: The RFC call may be timing out due to long processing times or network delays.
Solutions to TA231 RFC Error
Check Network Connectivity:
- Use tools like
ping
ortraceroute
to verify that the systems can communicate with each other.Verify RFC Destination:
- Go to transaction
SM59
and check the configuration of the RFC destination. Ensure that the connection type, target host, and system number are correct.- Test the connection from
SM59
to see if it is successful.Check Authorizations:
- Ensure that the user ID used for the RFC call has the necessary authorizations to execute the function module in the target system.
Check System Status:
- Verify that the target system is up and running. You can check the system status in transaction
SM51
or by logging into the target system directly.Review Function Module:
- Ensure that the function module being called exists in the target system and is active. You can check this in transaction
SE37
.Increase Timeout Settings:
- If timeouts are an issue, consider increasing the timeout settings in the RFC destination configuration in
SM59
.Check Logs:
- Review the system logs (transaction
SM21
) and the developer trace files (transactionST22
) for any additional error messages that may provide more context.Related Information
Transaction Codes:
SM59
: RFC DestinationsSM21
: System LogST22
: Dump AnalysisSE37
: Function ModuleSAP Notes: Check the SAP Support Portal for any relevant SAP Notes that may address specific issues related to RFC errors.
Documentation: Refer to the official SAP documentation for more details on RFC configuration and troubleshooting.
If the issue persists after trying the above solutions, it may be beneficial to consult with your SAP Basis team or reach out to SAP support for further assistance.
Get instant SAP help. Sign up for our Free Essentials Plan.
TA230
Log output will be exited, user master data will be deleted
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
TA229
Client is in import mode, start tp-import or processing after import
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
TA232
No RFC authorization in target system for process &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
TA233
Read or conversion error system: & table: &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.