How To Fix SRT_LPREG094 - No logicalport provided for &1. PI as default runtime is disabled.


SRT_LPREG094 - Overview

  • Message type: E = Error

  • Message class: SRT_LPREG - Logical Port Registry

  • Message number: 094

  • Message text: No logicalport provided for &1. PI as default runtime is disabled.

  • Show details Hide details
  • What causes this issue?

    PI is not the default for outbound consumer proxy call if no logical
    port is used.
    There is no default logical port defined for the consumer proxy &V1& and
    the proxy is instantiated without an explicit logical port name.

    How to fix this error?

    If PI should process the outbound call there are following options:
    Create a PI logical port or choose an existing PI logical port in
    SOAManager. Define it as default logical port.
    Adapt the coding and instantiate the consumer proxy &V1& with the name
    of a PI logical port.
    Enable PI as the default runtime (see below).
    If Web Service should process the outbound call there are two options:
    Create a Web Service logical port or choose an existing in SOAManager.
    Define it as default logical port.
    Adapt the coding and instantiate the consumer proxy &V1& with the name
    of a Web Service logical port.

    Procedure for System Administrators

    How to enable PI as default.
    Using transaction SOAManager:
    Go to 'Technical Administration'
    Select 'SAP Client Settings'
    Open 'PI Usage'
    Check 'Use PI as default if no logical port is used' and press 'Save'
    Using report SRT_WSP_PI_DEFAULT:
    Execute report
    <DS:REPN.SRT_WSP_PI_DEFAULT>SRT_WSP_PI_DEFAULT</>
    Check 'Use PI as default if no logical port is used' and press F8

    Error message extract from SAP system. Copyright SAP SE.


Smart SAP Assistant

  • What is the cause and solution for SAP error message SRT_LPREG094 - No logicalport provided for &1. PI as default runtime is disabled. ?
    The SAP error message SRT_LPREG094 indicates that there is no logical port provided for the specified service, and it also mentions that the Process Integration (PI) as the default runtime is disabled. This error typically occurs in scenarios involving SAP's web services or when using the SAP NetWeaver Process Integration (PI) or Process Orchestration (PO) for service calls.
    
    Cause: Missing Logical Port: The logical port for the web service is not defined in the SAP system. Logical ports are used to define the connection parameters for web service calls. PI Runtime Disabled: The default runtime for PI is disabled, which means that the system cannot use PI for processing the service call.
    Configuration Issues: There may be issues with the configuration of the web service or the logical port settings.
    Solution: Define a Logical Port: Go to transaction SOAMANAGER in your SAP system. Navigate to the Web Service Configuration section. Find the service for which the error is occurring. Create

    Already have an account? Login here!




Instant HelpGet instant SAP help. Sign up for our Free Essentials Plan.


Related SAP Error Messages

Click the links below to see the following related messages:

Click on this link to search all SAP messages.


Rating
ERPlingo simplifies finding the accurate answers to SAP message errors. I now use every week. A must have tool for anyone working with SAP! Highly recommended!
Rate 1
Kent Bettisworth
Executive SAP Consultant