Message type: E = Error
Message class: SPXN - Proxy Generation
Message number: 062
Message text: PortType {&2}&1 not found in WSDL
The specified PortType {&V2&}&V1& was not found in the WSDL.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Provide a PortType which is part of the WSDL. If just one PortType is
defined in the WSDL, the Porttype may be omitted.
Error message extract from SAP system. Copyright SAP SE.
SPXN062
- PortType {&2}&1 not found in WSDL ?The SAP error message SPXN062 indicates that a specific port type defined in a WSDL (Web Services Description Language) file cannot be found. This error typically occurs when working with SAP's web services, particularly when trying to consume or expose a web service.
Cause:
- Incorrect WSDL URL: The WSDL URL provided may be incorrect or inaccessible, leading to the inability to locate the specified port type.
- Missing Port Type: The port type specified in the error message may not be defined in the WSDL file. This could happen if the WSDL was modified or if the service was not properly generated.
- Version Mismatch: There may be a version mismatch between the WSDL and the service implementation, causing the expected port type to be absent.
- Network Issues: Network issues may prevent access to the WSDL file, leading to the inability to retrieve the necessary definitions.
Solution:
- Verify WSDL URL: Check the WSDL URL to ensure it is correct and accessible. You can try accessing the URL directly in a web browser to see if it returns the expected WSDL content.
- Check WSDL Content: Open the WSDL file and verify that the port type mentioned in the error message is indeed defined within it. If it is missing, you may need to regenerate the WSDL or correct the service definition.
- Regenerate WSDL: If you have access to the service implementation, consider regenerating the WSDL to ensure it includes all necessary definitions.
- Check Service Configuration: Ensure that the service is correctly configured in SAP and that all necessary components are activated.
- Network Troubleshooting: If there are network issues, check your network connection and firewall settings to ensure that they are not blocking access to the WSDL.
Related Information:
By following these steps, you should be able to identify the cause of the SPXN062 error and implement the appropriate solution.
Get instant SAP help. Sign up for our Free Essentials Plan.
SPXN061
Abap Length must be greater than xsd length
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
SPXN060
You can't assign Service Consumer and RFC Consumer to the same mapping
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
SPXN063
PortType must be specified
What causes this issue? No PortType specified.System Response The system issues an error message and will not allow you to continue with this transa...
SPXN064
Change may result in inconsistent existing enhancements
What causes this issue? You changed data type extensibility from dynamic to static.System Response The change is possible but already existing dynam...
Click on this link to search all SAP messages.