Message type: E = Error
Message class: SIW - Service Implementation Workbench
Message number: 087
Message text: Structure &1 has no field definition
The configuration had defined no fields for the structure object &1. The
structure object is not consistent.
SIW aborts the object creation since the structure definition is not
valid.
The generation of the object is not possible.
Define at least one field for the structure object description by using
the <DS><DS:IO.IF_SIW_STRU_PIECE_DESCR SET_METADATA_FOR_FIELDS>SET
_METADATA_FOR_FIELDS</></> method.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
SIW087
- Structure &1 has no field definition ?The SAP error message SIW087, which states "Structure &1 has no field definition," typically occurs when there is an issue with the structure definition in the SAP system. This error can arise in various contexts, such as during the execution of reports, data extraction, or when working with data models.
Cause: Missing Structure Definition: The structure referenced in the error message does not have any fields defined. This could be due to a missing or incomplete data dictionary object. Transport Issues: If the structure was recently transported from another system, it may not have been transported correctly, leading to missing definitions. Development Errors: If a developer has created or modified a structure but did not properly define its fields, this error can occur. Namespace Issues: If the structure is in a custom namespace and there are issues with the namespace configuration, it may not be recognized properly.
Solution: Check Structure Definition: Go to transaction SE11 (Data Dictionary). Enter the
Get instant SAP help. Sign up for our Free Essentials Plan.
SIW086
Name &1 of object &2 contains lower cases
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
SIW085
Signature Template name is missing for object &1
What causes this issue? The system could not identify the signature template for object &v1&.System Response The system cannot execute the g...
SIW088
Structure &2: Fieldname &1 is invalid
What causes this issue? The configuration of the structure object &v2& is inconsistent, because the FIELDNAME &v1& is invalid.System ...
SIW089
Structure &1: Field &2 contains wrong value for REFTYPE &3
What causes this issue? The value for type of object referenced &v3& is not supported.System Response The feasibility check of structure obj...
Click on this link to search all SAP messages.