Do you have any question about this error?
Message type: E = Error
Message class: /SCWM/WM_SEL -
Message number: 082
Message text: No entry found for process-oriented storage control for &1 &2 &3 &4
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/SCWM/WM_SEL082
- No entry found for process-oriented storage control for &1 &2 &3 &4 ?The SAP error message
/SCWM/WM_SEL082
indicates that there is no entry found for process-oriented storage control (POSC) for the specified parameters. This error typically occurs in the context of warehouse management processes, particularly when trying to execute a task that requires specific storage control settings.Cause:
The error can be caused by several factors, including:
- Missing Configuration: The process-oriented storage control settings for the specified warehouse, storage type, or storage bin may not be configured in the system.
- Incorrect Parameters: The parameters provided (like warehouse number, storage type, etc.) may not match any existing entries in the POSC configuration.
- Data Inconsistency: There may be inconsistencies in the master data or configuration settings that prevent the system from finding the appropriate entries.
- Transport Issues: If the configuration was recently transported from another system, it may not have been properly activated or may be incomplete.
Solution:
To resolve the error, you can take the following steps:
Check Configuration:
- Go to the transaction code
/SCWM/WM_POSC
to check the process-oriented storage control settings.- Ensure that there are entries for the specified warehouse number, storage type, and other relevant parameters.
Verify Parameters:
- Double-check the parameters you are using in the transaction or process that triggered the error. Ensure they are correct and correspond to existing entries in the system.
Maintain POSC Entries:
- If entries are missing, you may need to create or maintain the necessary POSC settings. This involves defining the relevant storage control strategies and linking them to the appropriate warehouse and storage types.
Check Master Data:
- Ensure that the master data (like storage types, storage bins, etc.) is correctly set up and consistent with the POSC configuration.
Transport and Activation:
- If the configuration was recently transported, ensure that it has been activated properly in the target system.
Consult Documentation:
- Refer to SAP documentation or help resources for detailed guidance on configuring process-oriented storage control.
Related Information:
/SCWM/WM_POSC
for POSC configuration and /SCWM/WM_STYPE
for storage type configuration.By following these steps, you should be able to identify the cause of the error and implement the necessary solutions to resolve it.
Get instant SAP help. Start your 7-day free trial now.
/SCWM/WM_SEL081
No entry found in table /SCWM/T301M for specified key
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/WM_SEL080
No entry found in table /SCWM/TANA for specified key
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/WM_SEL083
No storage sections found in warehouse number &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/WM_SEL084
No storage sections found in warehouse number &1 storage type &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.