Do you have any question about this error?
Message type: E = Error
Message class: /SCWM/WM_SEL -
Message number: 066
Message text: No product putaway profile found (putaway ctrl ind.:&1, storage type:&2)
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/SCWM/WM_SEL066
- No product putaway profile found (putaway ctrl ind.:&1, storage type:&2) ?The SAP error message
/SCWM/WM_SEL066
indicates that there is no product putaway profile found for the specified putaway control indicator and storage type. This error typically occurs in the context of warehouse management processes in SAP Extended Warehouse Management (EWM).Cause:
- Missing Putaway Profile: The most common cause is that the product you are trying to put away does not have an associated putaway profile defined in the system.
- Incorrect Configuration: The putaway control indicator or storage type may not be correctly configured or may not match the existing profiles.
- Product Master Data: The product master data may not be properly maintained, leading to the absence of a putaway profile.
- Warehouse Configuration: The warehouse configuration may not be set up to handle the specific storage type or putaway control indicator.
Solution:
Check Product Master Data:
- Go to the product master data in SAP EWM and ensure that a putaway profile is assigned to the product.
- If not, assign the appropriate putaway profile.
Define Putaway Profile:
- If a putaway profile does not exist, you may need to create one. This can be done in the SAP EWM configuration under the relevant settings for putaway profiles.
- Ensure that the putaway profile is linked to the correct putaway control indicator and storage type.
Review Putaway Control Indicator:
- Check the putaway control indicator settings to ensure they are correctly defined and linked to the appropriate storage types.
- Make sure that the putaway control indicator used in the transaction matches the one defined in the system.
Storage Type Configuration:
- Verify that the storage type is correctly configured in the system and that it is compatible with the putaway process you are trying to execute.
Testing:
- After making the necessary changes, test the putaway process again to ensure that the error is resolved.
Related Information:
/SCWM/MON
for monitoring or /SCWM/PRD
for product master data maintenance.By following these steps, you should be able to resolve the error message /SCWM/WM_SEL066
and successfully execute the putaway process in SAP EWM.
Get instant SAP help. Start your 7-day free trial now.
/SCWM/WM_SEL065
No storage bins found
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/WM_SEL064
No storage bin found
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/WM_SEL067
Packing station not found for route &1 and activity area &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/WM_SEL068
You do not have authorization to display stock
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.