How To Fix /SCWM/REM_BIN_DET122 - Source storage type &1 determined, no source storage bin determined


SAP Error Message - Details

  • Message type: E = Error

  • Message class: /SCWM/REM_BIN_DET -

  • Message number: 122

  • Message text: Source storage type &1 determined, no source storage bin determined

  • Show details Hide details


  • Self-Explanatory Message

    Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.

    To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.

    Unfortunately, there isn't any extra information in this error notice.



    What else can you do?

    First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).

    Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.

    You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.


Smart SAP Assistant

  • What is the cause and solution for SAP error message /SCWM/REM_BIN_DET122 - Source storage type &1 determined, no source storage bin determined ?

    The SAP error message /SCWM/REM_BIN_DET122 indicates that while processing a request in the Extended Warehouse Management (EWM) module, the system was able to determine a source storage type, but it could not find a specific source storage bin within that storage type. This can occur during various warehouse operations, such as picking, putaway, or stock transfer.

    Causes:

    1. Configuration Issues: The storage type may not have any bins defined, or the bins may not be properly configured.
    2. Stock Availability: There may be no stock available in the determined storage type, leading to the absence of a source bin.
    3. Warehouse Process Type: The warehouse process type may not be correctly set up to allow for the determination of bins.
    4. Bin Status: The bins in the determined storage type may be blocked or not available for the operation being performed.
    5. Master Data Issues: There may be issues with the master data, such as incorrect or missing information for the storage type or bins.

    Solutions:

    1. Check Storage Type Configuration:

      • Go to the configuration settings for the storage type in EWM and ensure that bins are defined and active.
      • Verify that the storage type is correctly set up to allow for the operations you are trying to perform.
    2. Review Stock Levels:

      • Check the stock levels in the determined storage type to ensure that there is stock available.
      • Use transaction codes like /SCWM/IS to check inventory levels.
    3. Examine Warehouse Process Types:

      • Ensure that the warehouse process type being used is correctly configured to allow for bin determination.
      • Check if the process type is linked to the correct storage type and bin determination strategy.
    4. Check Bin Status:

      • Review the status of the bins in the determined storage type to ensure they are not blocked or restricted.
      • Use transaction codes like /SCWM/BIN to check the status of the bins.
    5. Master Data Verification:

      • Verify that the master data for the storage type and bins is complete and accurate.
      • Ensure that the relevant material master data is also correctly set up.
    6. Debugging:

      • If the issue persists, consider debugging the bin determination logic to identify any specific issues in the determination process.

    Related Information:

    • Transaction Codes: Familiarize yourself with relevant transaction codes such as /SCWM/IS (Inventory Status), /SCWM/BIN (Bin Management), and /SCWM/REM (EWM Remnants).
    • SAP Notes: Check for any SAP Notes related to this error message for potential patches or updates that may resolve the issue.
    • Documentation: Review SAP documentation on EWM bin management and storage type configuration for best practices and troubleshooting steps.

    By following these steps, you should be able to identify the cause of the error and implement a solution to resolve it.

    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.


Related SAP Error Messages

Click the links below to see the following related messages:

Click on this link to search all SAP messages.


Rating
ERPlingo's SAP support assistant is amazing. Saves me countless hours trying to solve complex SAP issues myself. It's a real game changer!
Rate 1
Thomas Michael
SAP Consultant, Author & Speaker