Do you have any question about this error?
Message type: E = Error
Message class: /SCWM/PUT_BIN_DET -
Message number: 241
Message text: Input parameter for bin determination not correctly provided
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/SCWM/PUT_BIN_DET241
- Input parameter for bin determination not correctly provided ?The SAP error message
/SCWM/PUT_BIN_DET241
indicates that there is an issue with the input parameters provided for bin determination in the Extended Warehouse Management (EWM) module. This error typically arises when the system is unable to determine the appropriate storage bin for a given operation due to missing or incorrect input data.Causes:
- Missing Input Parameters: Required parameters for bin determination, such as product, warehouse, or storage type, may not be provided.
- Incorrect Configuration: The bin determination strategy may not be properly configured in the system, leading to failures in determining the correct bin.
- Data Inconsistencies: There may be inconsistencies in master data, such as product master or storage bin master data.
- Warehouse Process Type Issues: The warehouse process type being used may not be compatible with the bin determination logic.
- User Authorization: The user may not have the necessary authorizations to access certain data required for bin determination.
Solutions:
- Check Input Parameters: Ensure that all required input parameters for bin determination are correctly provided. This includes verifying that the product, warehouse, and storage type are specified.
- Review Configuration: Check the configuration settings for bin determination in the EWM system. Ensure that the bin determination strategy is correctly set up and that all necessary rules are defined.
- Validate Master Data: Review the master data for the product and storage bins to ensure that there are no inconsistencies or missing information.
- Examine Warehouse Process Types: Verify that the warehouse process type being used is appropriate for the operation and that it supports the required bin determination logic.
- Check User Authorizations: Ensure that the user executing the operation has the necessary authorizations to access the required data.
Related Information:
/SCWM/PRDI
(for product master) and /SCWM/BIN
(for storage bin master) to review the relevant data.By following these steps, you should be able to identify the root cause of the error and implement the necessary solutions to resolve it.
Get instant SAP help. Start your 7-day free trial now.
/SCWM/PUT_BIN_DET240
Input parameter for rough bin determination not correctly provided
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/PUT_BIN_DET239
No aisles/levels reachable from current location (CP/Resource)
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/PUT_BIN_DET242
No CP data found for storage bin &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/PUT_BIN_DET243
No WPT maintained for CP&1 (&2) or for PLC &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.