Do you have any question about this error?
Message type: E = Error
Message class: /SCWM/PUT_BIN_DET -
Message number: 072
Message text: No dest. bin determination. No valid stor.type/sec./bin type combinations
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
The SAP error message
/SCWM/PUT_BIN_DET072
indicates that the system is unable to determine a destination bin for a putaway process in the Extended Warehouse Management (EWM) module. This typically occurs when there are no valid combinations of storage type, storage section, and bin type defined for the putaway process.Cause:
- Missing Configuration: The most common cause is that the necessary configuration for storage types, storage sections, and bin types is not set up correctly in the system.
- Incompatible Storage Type: The storage type defined for the material or the warehouse process may not be compatible with the destination bin.
- Bin Type Restrictions: The bin type may have restrictions that prevent it from being used for the specific material or process.
- Storage Section Issues: If the storage section is not defined or is incorrectly configured, it can lead to this error.
- Material Master Data: The material master data may not be correctly set up for the warehouse, leading to issues in bin determination.
Solution:
Check Configuration:
- Go to the EWM configuration settings and verify that the storage types, storage sections, and bin types are correctly defined.
- Ensure that the combinations of storage type, storage section, and bin type are valid and active.
Review Material Master:
- Check the material master data for the relevant material to ensure that it is set up correctly for the warehouse.
- Ensure that the material is assigned to the correct storage type and that it has the necessary attributes for putaway.
Check Warehouse Process Types:
- Review the warehouse process types to ensure that they are correctly configured to allow for putaway into the desired bins.
Test Bin Determination:
- Use the bin determination functionality in the system to test if the system can find a valid bin for the material. This can often be done through transaction codes like
/SCWM/PRDI
or similar.Consult Documentation:
- Refer to SAP documentation or help resources for detailed guidance on configuring storage types, sections, and bin types.
Debugging:
- If the issue persists, consider debugging the bin determination process to identify where the failure occurs.
Related Information:
/SCWM/PRDI
(for putaway) and /SCWM/PUTAWAY
(for putaway processes).By following these steps, you should be able to identify the root cause of the error and implement the necessary changes to resolve it.
Get instant SAP help. Start your 7-day free trial now.
Feature | Free Access | Free Trial |
---|---|---|
Basic SAP error explanation | ![]() |
![]() |
Step-by-Step Usage Guide | ![]() |
![]() |
Interactive SAP Coach Assistance | ![]() |
![]() |
AI Troubleshooting for T-Code Errors | ![]() |
![]() |
/SCWM/PUT_BIN_DET071 Storage type &1: No putaway - max. storage type qty exceeded (current:&2)
What causes this issue? Available quantity: &V2& Maximum storage type q...
/SCWM/PUT_BIN_DET070 Maximum storage type quantity in storage type &1 (&2) is being checked
Self-Explanatory Message Since SAP believes that this specific error message is ...
/SCWM/PUT_BIN_DET073 Sort rule "Near to Fixed Bin" active f. finding empty bins (stor.type:&1)
Self-Explanatory Message Since SAP believes that this specific error message is ...
/SCWM/PUT_BIN_DET074 Addition to existing stock performed into storage bin &1
Self-Explanatory Message Since SAP believes that this specific error message is ...
SAP messages fall into 3 different categories: Error messages
(message type = E), Warnings (W) or Informational (I) messages.
An error message will prevent you from continuing your work - it is a hard stop and you need to fix the error before you can proceed. A warning message will stop your work, however, you can then bypass the warning by pressing the Enter key on your keyboard. That said, it is still good practice to investigate the cause of the warning message and address it. An information message will not stop your work and is truly just for informational purposes.
Click on this link to search all SAP messages.