Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: /SCWM/PUT_BIN_DET -
Message number: 010
Message text: No st. section search seq. found (st.tpe:&1,st.sec.ID:&2,Fnd1:&3,Fnd2:&4)
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/SCWM/PUT_BIN_DET010
- No st. section search seq. found (st.tpe:&1,st.sec.ID:&2,Fnd1:&3,Fnd2:&4) ?The SAP error message
/SCWM/PUT_BIN_DET010
indicates that the system could not find a storage section search sequence for the specified storage type and storage section. This error typically occurs in the context of warehouse management processes, particularly when trying to put away goods into a warehouse.Cause:
The error can be caused by several factors:
- Missing Configuration: The storage type or storage section may not have a defined search sequence in the system.
- Incorrect Master Data: The master data for the storage type or storage section may be incomplete or incorrectly configured.
- Warehouse Process Type: The warehouse process type being used may not be properly linked to the storage type or section.
- Custom Logic: If there are custom enhancements or logic in place, they may interfere with the standard search sequence.
Solution:
To resolve this error, you can take the following steps:
Check Storage Type and Section Configuration:
- Go to the configuration settings for the warehouse management module.
- Verify that the storage type and storage section are correctly defined and that a search sequence is assigned to them.
Define Search Sequence:
- If a search sequence is missing, you can define it in the configuration:
- Navigate to the relevant configuration path in SPRO:
Logistics Execution -> Warehouse Management -> Master Data -> Define Storage Type Search Sequence
.- Create or modify the search sequence to include the necessary storage types and sections.
Review Warehouse Process Types:
- Ensure that the warehouse process types are correctly set up and linked to the storage types and sections.
- Check if the process type being used for the putaway is appropriate for the storage type.
Check Master Data:
- Review the master data for the materials being put away to ensure they are correctly assigned to the appropriate storage types and sections.
Debug Custom Logic:
- If there are any custom enhancements or user exits that might affect the putaway process, review them to ensure they are not causing the issue.
Test the Configuration:
- After making changes, test the configuration by attempting to perform the putaway process again to see if the error persists.
Related Information:
SPRO
for configuration, LT01
for putaway, and LX01
for warehouse management monitoring.By following these steps, you should be able to identify and resolve the cause of the error message /SCWM/PUT_BIN_DET010
.
Get instant SAP help. Sign up for our Free Essentials Plan.
/SCWM/PUT_BIN_DET009
Search sequence &1 &2 contains no value
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/PUT_BIN_DET008
Determine destination storage type in warehouse number &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/PUT_BIN_DET011
Destination storage section check is not active in storage type &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/PUT_BIN_DET012
Destination storage section &1 is entered in storage type: &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.