Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/SCWM/PI_APPL215
- Storage bin &1 will not be considered during completeness check (BAdI) ?The SAP error message
/SCWM/PI_APPL215
indicates that a specific storage bin (denoted by&1
) is not being considered during the completeness check in the context of the Extended Warehouse Management (EWM) module. This message typically arises when there are issues related to the configuration of the storage bin or the settings in the Business Add-In (BAdI) that governs the completeness check.Cause:
Storage Bin Configuration: The storage bin may not be properly configured to be included in the completeness check. This could be due to settings that exclude certain bins based on their type, status, or other criteria.
BAdI Implementation: The BAdI implementation that is responsible for the completeness check may have logic that excludes certain storage bins based on specific conditions or criteria.
Warehouse Process Type: The warehouse process type associated with the storage bin may not be set up to allow for completeness checks.
Stock Type: The stock type in the storage bin may not be eligible for the completeness check, such as if it is marked as blocked or not usable.
Solution:
Check Storage Bin Configuration: Review the configuration of the storage bin in the EWM system. Ensure that it is set up correctly and is eligible for the completeness check.
Review BAdI Implementation: If a custom BAdI implementation is in place, review the logic to ensure that it does not inadvertently exclude the storage bin in question. You may need to adjust the conditions or logic to include the bin.
Warehouse Process Type Settings: Verify the settings for the warehouse process type associated with the storage bin. Ensure that it is configured to allow for completeness checks.
Stock Type Verification: Check the stock type in the storage bin. If it is blocked or not usable, consider moving the stock to a different bin that is eligible for the completeness check.
Consult Documentation: Refer to SAP documentation or notes related to the specific error message for additional insights or updates that may address the issue.
Testing: After making any changes, perform tests to ensure that the storage bin is now considered during the completeness check.
Related Information:
BAdI Documentation: Look for documentation related to the specific BAdI that is being used for the completeness check. This may provide insights into how it operates and what conditions it checks.
SAP Notes: Check SAP Notes for any known issues or patches related to this error message. SAP frequently updates its knowledge base with solutions to common problems.
EWM Configuration Guides: Review the EWM configuration guides for best practices on setting up storage bins and completeness checks.
Support Forums: Consider reaching out to SAP support or community forums for additional assistance if the issue persists after checking the above areas.
By following these steps, you should be able to identify the cause of the error message and implement a solution to ensure that the storage bin is considered during the completeness check.
Get instant SAP help. Start your 7-day free trial now.
/SCWM/PI_APPL210
Multiple rows selected; select only one row
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/PI_APPL206
Collect queue data
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/PI_APPL712
Logical system &1. Function module &2 does not exist.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/PI_APPL_REPORT000
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.