Message type: E = Error
Message class: /SCWM/MFS -
Message number: 480
Message text: PLC and PLC Object combination is used &1; Combination must be unique
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/SCWM/MFS480
- PLC and PLC Object combination is used &1; Combination must be unique ?The SAP error message
/SCWM/MFS480
indicates that there is a problem with the combination of the PLC (Process Line Control) and the PLC Object in the context of the SAP Extended Warehouse Management (EWM) system. Specifically, the error states that the combination of the PLC and PLC Object is not unique, which means that the system has found multiple entries for the same combination where it expects only one.Cause:
- Duplicate Entries: The most common cause of this error is that there are duplicate entries in the configuration for the PLC and PLC Object combination. This can happen if the same PLC is assigned to multiple PLC Objects or if there are multiple configurations that overlap.
- Incorrect Configuration: There may be an incorrect setup in the system where the PLC and PLC Object combinations are not properly defined.
- Data Migration Issues: If data has been migrated from another system or if there have been recent changes in the configuration, it may lead to inconsistencies.
Solution:
- Check Configuration: Go to the configuration settings for the PLC and PLC Object in the SAP EWM system. Ensure that each PLC is uniquely assigned to a PLC Object. You can do this by navigating to the relevant configuration transaction in SAP.
- Identify Duplicates: Use transaction codes like
/SCWM/MFS
or relevant reports to identify any duplicate entries for the PLC and PLC Object combination. You may need to run a query or report to find where the duplicates exist.- Remove Duplicates: Once you have identified the duplicates, you will need to remove or correct them to ensure that each PLC and PLC Object combination is unique.
- Testing: After making changes, test the configuration to ensure that the error no longer occurs and that the system behaves as expected.
- Consult Documentation: If you are unsure about the configuration, refer to the SAP documentation or help guides related to EWM and MFS (Material Flow System) for detailed instructions.
Related Information:
/SCWM/MFS
for managing MFS settings.By following these steps, you should be able to resolve the error and ensure that your PLC and PLC Object combinations are correctly configured in the SAP EWM system.
Get instant SAP help. Start your 7-day free trial now.
/SCWM/MFS471
MFS integration is not supported
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/MFS470
Tare weight of the HU is set to zero
What causes this issue? The measured total weight in the telegram is less than the tare weight of the HU.System Response The tare weight of the HU i...
/SCWM/MFS481
Enter the EWM object and PLC object
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/MFS500
Maintain aisle and/or level
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.