Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/SCWM/MFS184
- Determining storage control data for communication point &1 &2 ?The SAP error message
/SCWM/MFS184
indicates an issue with determining storage control data for a communication point in the context of the SAP Extended Warehouse Management (EWM) system, particularly when dealing with the Material Flow System (MFS). This error typically arises when the system is unable to find the necessary storage control data for a specific communication point, which can hinder the proper functioning of warehouse processes.Causes:
- Missing Configuration: The communication point may not be properly configured in the system. This could include missing or incorrect settings in the storage control or communication point definitions.
- Data Inconsistency: There may be inconsistencies in the master data related to the storage control or communication points.
- Incorrect Parameters: The parameters being passed to the system for the communication point may be incorrect or incomplete.
- Transport Issues: If there are issues with the transport of data between systems (e.g., between EWM and MFS), this could lead to the error.
- Authorization Issues: Lack of proper authorizations for accessing the required data could also trigger this error.
Solutions:
- Check Configuration: Verify the configuration of the communication point in the system. Ensure that all necessary settings are correctly defined in the storage control and communication point settings.
- Review Master Data: Check the master data related to the storage control and communication points for any inconsistencies or missing entries.
- Validate Parameters: Ensure that the parameters being used in the process are correct and complete. This includes checking any relevant transaction codes or function modules.
- Transport Check: If applicable, check for any transport issues that may be affecting the data flow between systems. Ensure that all necessary transports have been successfully completed.
- Authorization Check: Verify that the user has the necessary authorizations to access the required data. If not, work with your security team to obtain the necessary permissions.
- Debugging: If the issue persists, consider using debugging tools to trace the execution of the relevant processes and identify where the failure occurs.
Related Information:
If the problem continues after following these steps, it may be beneficial to reach out to SAP support for further assistance.
Get instant SAP help. Start your 7-day free trial now.
/SCWM/MFS183
Determining storage control data for WT &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/MFS182
WT created for clarific. bin &1 outside of automatic storage retrieval
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/MFS185
Unable to create WT as storage control date could not be determined
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/MFS186
***** Start FM /SCWM/MFSACT_WT_CONFIRM for HU &1 (&2) *****
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.