    Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.

    To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.

    Unfortunately, there isn't any extra information in this error notice.



    What else can you do?

    First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).

    Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.

    You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.


Smart SAP Assistant

  • What is the cause and solution for SAP error message /SCWM/MFS042 - Application data for communic. channel &1 of PLC &2 (whse &3) not defined ?

    The SAP error message /SCWM/MFS042 indicates that there is an issue with the configuration of the communication channel for a PLC (Programmable Logic Controller) in the context of the SAP Extended Warehouse Management (EWM) system. Specifically, it means that the application data for the specified communication channel and PLC is not defined.

    Cause:

    1. Missing Configuration: The communication channel for the specified PLC has not been properly configured in the system.
    2. Incorrect Channel Assignment: The channel may not be assigned to the correct warehouse or may not be linked to the appropriate PLC.
    3. Data Inconsistency: There may be inconsistencies in the data related to the communication channel or PLC configuration.
    4. Transport Issues: If the configuration was recently transported from another system, it may not have been fully set up in the target system.

    Solution:

    1. Check Configuration:

      • Go to the SAP EWM configuration settings and verify that the communication channel for the specified PLC is defined.
      • Ensure that the channel is correctly assigned to the warehouse in question.
    2. Define Communication Channel:

      • If the communication channel is not defined, you will need to create it. This can typically be done in the SAP EWM configuration under the relevant settings for MFS (Material Flow System).
      • Ensure that all necessary parameters for the communication channel are filled out correctly.
    3. Review PLC Settings:

      • Check the settings for the PLC to ensure that it is correctly configured and linked to the communication channel.
      • Verify that the PLC is active and operational.
    4. Transport Check:

      • If the configuration was transported, check the transport logs for any errors or issues that may have occurred during the transport process.
      • Ensure that all necessary objects were included in the transport request.
    5. Consult Documentation:

      • Refer to SAP documentation or help resources for specific guidance on configuring MFS and communication channels.
    6. Testing:

      • After making the necessary changes, test the communication channel to ensure that it is functioning correctly.

    Related Information:

    • Transaction Codes: You may need to use transaction codes such as /SCWM/MFS for MFS configuration or SPRO for general configuration settings.
    • SAP Notes: Check for any relevant SAP Notes that may address known issues or provide additional guidance on this error message.
    • Support: If the issue persists after checking the configuration, consider reaching out to SAP support for further assistance.

    By following these steps, you should be able to resolve the error message /SCWM/MFS042 and ensure that the communication channel for the PLC is properly defined and operational.

    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.


Related SAP Error Messages

Click the links below to see the following related messages:

Click on this link to search all SAP messages.


Rating
ERPlingo simplifies finding the accurate answers to SAP message errors. I now use every week. A must have tool for anyone working with SAP! Highly recommended!
Rate 1
Kent Bettisworth
Executive SAP Consultant