Do you have any question about this error?
Message type: E = Error
Message class: /SCWM/LT -
Message number: 421
Message text: BC-Set &1 cannot be activated in SAP S/4HANA EWM
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/SCWM/LT421
- BC-Set &1 cannot be activated in SAP S/4HANA EWM ?The SAP error message
/SCWM/LT421 BC-Set &1 cannot be activated
in the context of SAP S/4HANA Extended Warehouse Management (EWM) typically indicates an issue with activating a Business Configuration Set (BC-Set) that is required for certain functionalities within EWM. This error can arise due to various reasons, including missing prerequisites, configuration issues, or inconsistencies in the system.Causes:
- Missing Prerequisites: The BC-Set you are trying to activate may depend on other configuration settings or BC-Sets that have not been activated or configured properly.
- Inconsistent System State: There may be inconsistencies in the system that prevent the activation of the BC-Set.
- Authorization Issues: The user attempting to activate the BC-Set may not have the necessary authorizations.
- Incorrect System Configuration: The system may not be configured correctly for the specific EWM functionalities you are trying to use.
- Version Compatibility: The BC-Set may not be compatible with the version of SAP S/4HANA EWM you are using.
Solutions:
- Check Prerequisites: Review the documentation for the specific BC-Set to ensure that all prerequisites are met. Activate any required BC-Sets or configurations first.
- Review Logs: Check the system logs (transaction SLG1) for more detailed error messages that can provide insights into why the activation failed.
- Authorization Check: Ensure that the user has the necessary authorizations to activate BC-Sets. You may need to consult with your security team to verify this.
- System Consistency Check: Use transaction codes like
SICF
orSMD
to check for inconsistencies in the system. You may also want to run the transactionSFW5
to check for any inconsistencies in the business functions.- Consult SAP Notes: Search for relevant SAP Notes in the SAP Support Portal that may address known issues with the specific BC-Set or provide guidance on activation.
- Contact SAP Support: If the issue persists, consider reaching out to SAP Support for assistance. Provide them with the error message details and any logs you have reviewed.
Related Information:
/SCWM/BCSET
for managing BC-Sets, and SLG1
for viewing application logs.By following these steps, you should be able to identify the cause of the error and implement a solution to activate the required BC-Set in SAP S/4HANA EWM.
Get instant SAP help. Start your 7-day free trial now.
/SCWM/LT420
'Putaway complete' has to be active for storage type role &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/LT419
Storage type &1: Multi-depth storage restricted to a certain scenario
What causes this issue? Multi-depth storage is only allowed when the following conditions are met: Storage type role: ' ' - <LS>Stand...
/SCWM/LT422
Use fixed bins flag must be 'blank' for behavior &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/LT423
Putaway rules type æempty binÆ is not allowed for &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.