Do you have any question about this error?
Message type: E = Error
Message class: /SCWM/LM_CORE_APPL -
Message number: 025
Message text: No conversion between &1 and &2 was found
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/SCWM/LM_CORE_APPL025
- No conversion between &1 and &2 was found ?The SAP error message
/SCWM/LM_CORE_APPL025 No conversion between &1 and &2 was found
typically occurs in the context of the SAP Extended Warehouse Management (EWM) system, particularly when dealing with logistics and warehouse management processes. This error indicates that the system is unable to find a conversion between two specified units of measure (UoM) or data types.Cause:
- Missing Conversion Entries: The most common cause of this error is that there are no defined conversion factors between the two units of measure (UoM) or data types specified in the error message.
- Incorrect Configuration: The configuration for unit conversions in the system may not be set up correctly, leading to the inability to convert between the specified units.
- Data Entry Errors: There may be a mistake in the data entry where the wrong units are being used or referenced.
- Custom Development: If there are custom developments or enhancements in the system, they may not handle the conversion properly.
Solution:
Check Unit of Measure Configuration:
- Go to the transaction code
CUNI
(Maintain Units of Measure) in SAP.- Verify that the necessary conversion factors between the two units of measure are defined. If not, you will need to create the appropriate conversion entries.
Define Conversion Factors:
- If the conversion does not exist, you can create it by specifying the base unit and the corresponding unit along with the conversion factor.
Review Master Data:
- Check the master data (like material master, batch master, etc.) to ensure that the correct units of measure are being used and that they are consistent across the relevant documents.
Check Custom Code:
- If there are any custom developments, review the code to ensure that it correctly handles unit conversions and does not bypass standard conversion logic.
Consult Documentation:
- Review SAP documentation or notes related to unit conversions in EWM to ensure that you are following best practices.
Testing:
- After making changes, perform tests to ensure that the error no longer occurs and that the conversions are functioning as expected.
Related Information:
CUNI
for unit of measure maintenance and MM03
for material master data review.By following these steps, you should be able to identify the cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
/SCWM/LM_CORE_APPL024
No preprocessing header found for &1 &2 &3
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/LM_CORE_APPL023
Conditions and percentages must not be filled at the same time
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/LM_CORE_APPL026
Converting &1 to &2 leads to an overflow
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/LM_CORE_APPL027
Unable to execute quantity conversion; contact system administrator
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.