Do you have any question about this error?
Message type: E = Error
Message class: /SCWM/DELIVERY_UI -
Message number: 108
Message text: The RFC destination could not be determined for logical system &1
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/SCWM/DELIVERY_UI108
- The RFC destination could not be determined for logical system &1 ?The SAP error message
/SCWM/DELIVERY_UI108
indicates that the system is unable to determine the RFC (Remote Function Call) destination for a specified logical system. This can occur in various scenarios, particularly when working with SAP Extended Warehouse Management (EWM) or when integrating with other SAP systems.Cause:
- Missing or Incorrect RFC Destination: The logical system specified in the error message does not have a corresponding RFC destination defined in the SAP system.
- Configuration Issues: The logical system may not be properly configured in the system landscape.
- Authorization Issues: The user may not have the necessary authorizations to access the RFC destination.
- Network Issues: There may be network connectivity issues preventing the system from reaching the specified logical system.
Solution:
Check RFC Destination:
- Go to transaction
SM59
in the SAP GUI.- Look for the RFC destination that corresponds to the logical system mentioned in the error message.
- If it does not exist, create a new RFC destination with the appropriate settings.
Verify Logical System Configuration:
- Check the configuration of the logical system in transaction
SPRO
.- Navigate to
SAP Customizing Implementation Guide
>Logistics Execution
>Extended Warehouse Management
>Integration with Other SAP Systems
>Define Logical Systems
.- Ensure that the logical system is correctly defined and assigned.
Check Authorizations:
- Ensure that the user has the necessary authorizations to access the RFC destination.
- You may need to check the roles and profiles assigned to the user.
Test RFC Connection:
- In transaction
SM59
, select the RFC destination and use the "Connection Test" option to verify that the connection is working properly.Check Network Connectivity:
- Ensure that there are no network issues preventing communication between the systems.
- You may need to involve your network team to troubleshoot any connectivity problems.
Review System Logs:
- Check the system logs for any additional error messages or information that may provide more context about the issue.
Related Information:
SM59
: RFC DestinationsSPRO
: Customizing Implementation GuideSLG1
: Application LogBy following these steps, you should be able to identify and resolve the issue causing the error message /SCWM/DELIVERY_UI108
.
Get instant SAP help. Start your 7-day free trial now.
/SCWM/DELIVERY_UI107
The logical system could not be determined for business system &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/DELIVERY_UI106
No business system could be determined for logical system &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/DELIVERY_UI109
Changing warehouse door for item &1 using field control is not allowed
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/DELIVERY_UI110
Error in BAdI implementation; logical field name &1 already mapped
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.