Do you have any question about this error?
Message type: E = Error
Message class: /SCWM/CONS_CHECK -
Message number: 006
Message text: Max. no. of HUs is not divided correctly for main bin &1
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/SCWM/CONS_CHECK006
- Max. no. of HUs is not divided correctly for main bin &1 ?The SAP error message
/SCWM/CONS_CHECK006 Max. no. of HUs is not divided correctly for main bin &1
typically occurs in the context of warehouse management within the SAP Extended Warehouse Management (EWM) module. This error indicates that the maximum number of Handling Units (HUs) that can be stored in a specific main bin is not configured correctly or is not being adhered to.Cause:
- Configuration Issue: The maximum number of HUs allowed in the main bin may not be set correctly in the system configuration.
- Inconsistent Data: There may be inconsistencies in the data related to the handling units or the main bin.
- Warehouse Process: The process being executed may be trying to place more HUs in the main bin than what is allowed based on the configuration.
- Bin Capacity: The bin capacity settings may not align with the actual handling units being processed.
Solution:
Check Configuration:
- Go to the EWM configuration settings and verify the maximum number of HUs allowed for the specific main bin. This can usually be found in the bin type settings or warehouse structure settings.
- Ensure that the configuration aligns with the physical capacity of the bin.
Review Handling Units:
- Check the handling units that are being processed and ensure that they are correctly defined and that their quantities do not exceed the maximum allowed in the main bin.
Adjust Bin Capacity:
- If necessary, adjust the bin capacity settings to accommodate the number of HUs you need to store. This may involve increasing the maximum number of HUs allowed in the main bin.
Data Consistency Check:
- Perform a data consistency check to ensure that there are no discrepancies in the handling unit data or bin data.
Consult Documentation:
- Refer to SAP documentation or help resources for specific configuration steps related to handling units and bin management.
Testing:
- After making changes, conduct tests to ensure that the error does not reoccur and that the system behaves as expected.
Related Information:
/SCWM/PRDI
for product data, /SCWM/BIN
for bin management, or /SCWM/HU
for handling unit management.By following these steps, you should be able to identify the root cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
/SCWM/CONS_CHECK005
Main bin &1 attributes are not divided correctly for the sub-bins
What causes this issue? The main storage bin &V1& is divided into sub-bins but the main bin's attributes are not subdivided into equal p...
/SCWM/CONS_CHECK004
Storage bin &1 should not be divided
What causes this issue? There is no putaway task that refers to the main bin, and there is no stock in any of the sub-bins. This means that the stora...
/SCWM/CONS_CHECK007
Storage bins contain incorrect HU type &1
What causes this issue? Handling unit type &V1& is not allowed for storage bins.System Response The system issues an error message and will ...
/SCWM/CONS_CHECK008
Internal error occured while checking avail. qty; processing terminated
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.