Do you have any question about this error?
Message type: E = Error
Message class: /SCWM/CCHECK -
Message number: 505
Message text: Door &1 and door act. &2 with different START_ACTUAL or END_ACTUAL
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/SCWM/CCHECK505
- Door &1 and door act. &2 with different START_ACTUAL or END_ACTUAL ?The SAP error message
/SCWM/CCHECK505
typically occurs in the context of the Extended Warehouse Management (EWM) module. This error indicates that there is a mismatch between the start or end actual times of a door and the door activity associated with it. Specifically, the message states that the door and the door activity have differentSTART_ACTUAL
orEND_ACTUAL
timestamps.Cause:
- Data Entry Errors: The most common cause is incorrect data entry when creating or updating the door activity or the door itself.
- System Configuration Issues: There may be configuration issues in the EWM system that lead to discrepancies in the timestamps.
- Concurrent Activities: If multiple activities are being processed simultaneously, it may lead to timing conflicts.
- Incomplete Processes: If a previous process involving the door was not completed properly, it could lead to inconsistencies in the timestamps.
Solution:
- Verify Data: Check the timestamps for both the door and the door activity. Ensure that they are consistent and correctly entered.
- Correct Entries: If discrepancies are found, correct the
START_ACTUAL
andEND_ACTUAL
times to match between the door and the door activity.- Review Configuration: Ensure that the EWM configuration for doors and activities is set up correctly. This may involve checking the settings in the EWM customizing.
- Check for Concurrent Processes: Investigate if there are any concurrent processes that might be affecting the door activity. If so, resolve any conflicts.
- Reprocess Activities: If the issue persists, consider reprocessing the door activity or the related processes to ensure that all data is synchronized.
- Consult Documentation: Refer to SAP documentation or notes related to this specific error for any additional troubleshooting steps or patches that may be available.
Related Information:
/SCWM/DOOR
or /SCWM/ACTIVITY
to view and manage door and activity data.By following these steps, you should be able to identify and resolve the cause of the /SCWM/CCHECK505
error in your SAP EWM system.
Get instant SAP help. Start your 7-day free trial now.
/SCWM/CCHECK504
Entry (door &2; door act. &1) deleted from /SCWM/TU_DOOR
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/CCHECK503
TU/Door assignment &2 without door act. &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/CCHECK506
START_ACTUAL &1 and END_ACTUAL &2 must be copied from /SCWM/TU_DOOR
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/CCHECK507
END_ACTUAL &1 of /SCWM/DOOR_SRACT must be copied to /SCWM/TU_DOOR
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...