Do you have any question about this error?
Message type: E = Error
Message class: SCTS_HDI - Messages for CTS HDI API
Message number: 513
Message text: Data container &1 cannot have any references
Data containers cannot reference other containers or schemas.
Remove the references from the data container by deleting the name of
the reference from the corresponding field.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
SCTS_HDI513
- Data container &1 cannot have any references ?The SAP error message SCTS_HDI513 indicates that there is an issue with a data container in the SAP HANA database. Specifically, it states that the data container (identified by &1) cannot have any references. This error typically arises in the context of SAP HANA development, particularly when working with HDI (HANA Deployment Infrastructure) containers.
Cause:
The error usually occurs due to one of the following reasons:
- Invalid Configuration: The data container is configured in a way that does not allow references to other objects or containers.
- Dependency Issues: There may be dependencies or references to other objects that are not allowed within the context of the data container.
- Container Type Restrictions: Certain types of containers (like those meant for specific purposes) may have restrictions on references to ensure data integrity or performance.
Solution:
To resolve the SCTS_HDI513 error, you can take the following steps:
Check Container Configuration: Review the configuration of the data container to ensure that it is set up correctly and does not have any invalid references.
Review Dependencies: Look for any dependencies or references to other objects that may not be allowed. If there are references, consider removing them or restructuring your design.
Container Type: Ensure that you are using the correct type of data container for your use case. If the container type does not support references, you may need to create a different type of container.
Consult Documentation: Refer to the SAP HANA documentation for guidelines on data container configurations and restrictions. This can provide insights into what is permissible within your specific container type.
Recreate the Container: If the issue persists, consider recreating the data container from scratch, ensuring that you follow the correct procedures and configurations.
Check for Updates: Ensure that your SAP HANA system is up to date, as updates may include fixes for known issues related to HDI containers.
Related Information:
If the problem continues after trying these solutions, consider reaching out to SAP support for further assistance.
Get instant SAP help. Start your 7-day free trial now.
SCTS_HDI512
HDI container &1 is already active; container deployment not required
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
SCTS_HDI511
&1 does not reference any containers/schemas (nothing to check)
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
SCTS_HDI514
&1 &2 cannot reference API container &3
What causes this issue? API containers can only be referenced by other API containers.How to fix this error? Remove the reference to the API contain...
SCTS_HDI515
Checking inactive version of container &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.