Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: SCPR - BC Sets
Message number: 779
Message text: BC Set &1: No activation in Switch BC Set creation systems
BC Set '&V1&' is cross-client. Cross-client BC Sets are not activated
in 'Switch BC Set Creation Systems'. A system is a Switch BC Set
creation system if at least one client is configured as a 'Switch BC Set
Creation Client'. You can see or make this setting per client, in the
transaction 'SCC4' in 'Changing Switch Customizing', under 'Creating
Switch BC Sets'.
The BC Set was not activated.
No action is usually necessary, because the data in the BC Set is not
for the current system.
If the BC Set data is required in the system, copy it manually.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
SCPR779
- BC Set &1: No activation in Switch BC Set creation systems ?The SAP error message SCPR779 indicates that there is an issue with the activation of a Business Configuration Set (BC Set) in the context of a Switch Framework. This error typically arises when you are trying to create or activate a BC Set in a system that is not properly configured or does not have the necessary settings enabled.
Cause:
- Switch Framework Not Active: The system may not have the Switch Framework activated, which is necessary for managing BC Sets.
- Incorrect Configuration: The configuration settings for the BC Set or the Switch Framework may not be correctly set up.
- Missing Authorizations: The user may lack the necessary authorizations to create or activate BC Sets.
- System Landscape Issues: The system landscape may not be properly aligned, meaning that the source and target systems for the BC Set are not correctly configured.
Solution:
Activate the Switch Framework:
- Ensure that the Switch Framework is activated in your system. You can do this by navigating to the transaction code
SCPR20
and checking the status of the Switch Framework.- If it is not active, you may need to activate it according to your project requirements.
Check Configuration:
- Review the configuration settings for the BC Set. Ensure that all necessary parameters are correctly set.
- Use transaction
SCPR20
to check the settings and make adjustments as needed.User Authorizations:
- Verify that the user attempting to create or activate the BC Set has the necessary authorizations. This may involve checking roles and permissions in the user profile.
System Landscape Alignment:
- Ensure that the system landscape is properly aligned. This includes checking that the source and target systems for the BC Set are correctly configured and that any necessary transport routes are established.
Consult Documentation:
- Refer to SAP documentation or notes related to the specific version of your SAP system for any additional troubleshooting steps or known issues.
Contact SAP Support:
- If the issue persists after checking the above points, consider reaching out to SAP Support for further assistance. They may provide specific notes or patches that address the issue.
Related Information:
SCPR20
: Manage Switch FrameworkSCPR20
: Manage BC SetsBy following these steps, you should be able to identify and resolve the SCPR779 error in your SAP system.
Get instant SAP help. Sign up for our Free Essentials Plan.
SCPR778
Client setting "Creating Switch BC Sets": '&1'
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
SCPR777
Error reading data for customizing object '&1' (table '&2')
What causes this issue? An error occurred when reading information for the customizing object &V1& of database table &V2&. This data ...
SCPR780
BC Set &1: The BC Set does not contain language-dependent data
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
SCPR781
Classify the Switch BC Set (client-dependence/cascading)
What causes this issue? The contents of a Switch BC Set must be classified (client-specific data and/or data cascading in different clients). This ha...
Click on this link to search all SAP messages.