Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: SCPR - BC Sets
Message number: 520
Message text: Table/view &1 cannot be used in BC Sets
You cannot put the view or table with text table (S table) '&V1&' in a
BC Set.
This can be because:
There is no piece list (there must be tables in the transaction SOBJ,
from which the data is read, for each BC Set-relevant view or S table).
The view/S table has a BEFORE-EXPORT method which may only fill the
tables when they are exported from the system. As the BC Set does not
know this logic, the data is not copied.
The maintenance dialog is based on the table maintenance tools (SM30,
SM34, SM30/SM34 parameter transactions) and manual actions, which fill
tables in the background, run at events.
If it is a view, its definition could be inconsistent:
There are gaps in the key: All key fields must be consecutive at the
beginning of the view.
A key field is a GUID (Global Unique Identifier) or is longer than 255
characters (e.g. a field of data type STRING).
The view is "READ ONLY".
Parts of the view are not assigned to a customizing delivery class.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
If it is a table, it must beYou cannot put the view/S table in BC Sets.
Contact your system administrator or the SAP person responsible for this
view/S table.
Error message extract from SAP system. Copyright SAP SE.
SCPR520
- Table/view &1 cannot be used in BC Sets ?The SAP error message SCPR520 indicates that a specific table or view cannot be used in Business Configuration Sets (BC Sets). This error typically arises when you attempt to include a table or view in a BC Set that is not allowed due to certain restrictions or limitations.
Cause:
- Incompatible Object: The table or view you are trying to include in the BC Set is not compatible with BC Sets. This can happen if the object is not designed to be part of configuration settings or if it is a transient object.
- Technical Restrictions: Some tables or views are restricted from being included in BC Sets due to their nature (e.g., they may contain data that is not configuration-related).
- Custom Development: If the table or view is a custom development, it may not have been properly defined to be included in BC Sets.
Solution:
- Check Compatibility: Verify if the table or view is intended to be used in BC Sets. You can refer to SAP documentation or consult with your SAP Basis or development team.
- Use Alternative Objects: If the object cannot be included in a BC Set, consider using alternative configuration objects that are compatible.
- Customizing: If you are working with a custom table or view, ensure that it is defined correctly in the system. You may need to adjust its attributes or settings to make it compatible with BC Sets.
- Consult SAP Notes: Check for any relevant SAP Notes that might address this issue. SAP frequently updates its knowledge base with solutions for common problems.
- Contact SAP Support: If you are unable to resolve the issue, consider reaching out to SAP Support for assistance.
Related Information:
By understanding the cause of the SCPR520 error and following the suggested solutions, you should be able to address the issue effectively.
Get instant SAP help. Sign up for our Free Essentials Plan.
SCPR519
Select the BC Sets to be deleted
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
SCPR518
No restrictions on use in BC Sets
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
SCPR521
Table &1 is already assigned to the current object &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
SCPR522
You cannot put system object &1 in a BC Set
What causes this issue? The table &V1& is a system object. These are tables which either belong to the ABAP Dictionary or are internal SAP sy...
Click on this link to search all SAP messages.