Do you have any question about this error?
Message type: E = Error
Message class: /SCMTMS/COND -
Message number: 071
Message text: Field name is required when you use a table type with no structure
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/SCMTMS/COND071
- Field name is required when you use a table type with no structure ?The SAP error message
/SCMTMS/COND071 Field name is required when you use a table type with no structure
typically occurs in the context of SAP Transportation Management (TM) when there is an issue with the definition of a table type in ABAP code. This error indicates that a table type is being used without a defined structure, which is necessary for the system to understand how to handle the data.Cause:
- Undefined Structure: The table type being referenced does not have an associated structure defined. In ABAP, a table type must be linked to a structure that defines the fields it contains.
- Incorrect Data Declaration: The code may be attempting to declare a table type without specifying the necessary structure, leading to ambiguity in the data handling.
- Changes in Data Dictionary: If there have been recent changes in the Data Dictionary (like deletion or modification of a structure), it could lead to this error.
Solution:
Define a Structure: Ensure that the table type you are using is associated with a valid structure. You can create a new structure in the Data Dictionary (SE11) if one does not exist.
- Go to transaction SE11.
- Create a new structure or modify an existing one to include the necessary fields.
- Ensure that the structure is activated.
Check Table Type Declaration: Review the ABAP code where the table type is declared. Make sure that it is correctly referencing a defined structure.
Example of correct declaration:
TYPES: BEGIN OF ty_my_structure, field1 TYPE string, field2 TYPE i, END OF ty_my_structure. TYPES: tt_my_table TYPE TABLE OF ty_my_structure.
Review Code Logic: If the error occurs during runtime, check the logic that populates or manipulates the table type. Ensure that the operations being performed are valid for the defined structure.
Transport Requests: If the issue arose after a transport, ensure that all related objects (structures, table types) were included in the transport request and are correctly activated in the target system.
Debugging: If the error persists, consider debugging the program to identify the exact point of failure. This can provide insights into what is being passed to the table type and why it is failing.
Related Information:
By following these steps, you should be able to resolve the /SCMTMS/COND071
error and ensure that your ABAP code correctly utilizes table types with the necessary structures.
Get instant SAP help. Start your 7-day free trial now.
/SCMTMS/COND070
Table-based input supported only for conditions based on BRF+ expression
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCMTMS/COND069
Only default DAD can be used for condition type &1; &2 is not default DAD
What causes this issue? Only the data access definitions assigned to the condition type can be used for the condition type. If other data access defi...
/SCMTMS/COND072
Assigned data crawler &1 uses incorrect start BO node
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCMTMS/COND073
Data crawler step &1 must not be defined without data crawler profile
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.