Do you have any question about this error?
Message type: E = Error
Message class: /SAPCND/GENERATOR -
Message number: 606
Message text: Placeholder &1 is not defined (FM &2)
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/SAPCND/GENERATOR606
- Placeholder &1 is not defined (FM &2) ?The SAP error message
/SAPCND/GENERATOR606
indicates that a placeholder (represented by&1
) is not defined in the context of a function module (FM) identified by&2
. This error typically arises in the context of SAP Converged Data Management (CDM) or when working with condition management in SAP.Cause:
- Undefined Placeholder: The placeholder specified in the error message is not defined in the relevant context or configuration. This could be due to a missing entry in a configuration table or an incorrect reference in the function module.
- Function Module Issues: The function module referenced may not be properly implemented or may not have the necessary data to resolve the placeholder.
- Configuration Errors: There may be issues in the configuration of the condition management or the related data structures.
Solution:
Check Placeholder Definition:
- Verify that the placeholder
&1
is defined in the relevant configuration. This can typically be done by checking the condition tables or the configuration settings in the SAP system.- Ensure that the placeholder is correctly spelled and matches the expected format.
Review Function Module:
- Check the implementation of the function module
&2
to ensure that it is correctly set up to handle the placeholders.- Look for any missing logic or data retrieval that might be causing the placeholder to be undefined.
Configuration Review:
- Review the configuration settings related to the condition management or the specific area where the error is occurring. Ensure that all necessary entries are present and correctly configured.
- If applicable, consult the documentation or SAP notes related to the specific version of the software you are using.
Debugging:
- If the issue persists, consider debugging the function module to trace where the placeholder is being referenced and why it is not defined.
- Use transaction codes like SE37 (Function Module) or SE80 (Object Navigator) to analyze the function module and its dependencies.
SAP Notes and Support:
- Check the SAP Support Portal for any relevant SAP Notes that might address this specific error message. There may be patches or updates that resolve known issues.
- If necessary, reach out to SAP support for assistance, providing them with the error details and context.
Related Information:
By following these steps, you should be able to identify the cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
/SAPCND/GENERATOR605
Access program for &1(&2) could not be generated
What causes this issue? The access program for access <(>&<)>v2& of access sequence <(>&<)>v1& could not be g...
/SAPCND/GENERATOR604
Access program successfully generated for &1(&2)
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SAPCND/GENERATOR607
Error interpreting generation context
What causes this issue? Error interpreting generation context.System Response The selected action cannot be carried out. The system has probably tri...
/SAPCND/GENERATOR608
Parameter &1 not defined (FM &2)
What causes this issue? Parameter &v1& is not defined (FM &v2&).System Response The selected action cannot be carried out. The syste...
Click on this link to search all SAP messages.