Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: /SAPCND/GENERATOR -
Message number: 293
Message text: Access structure &1 was activated with a warning
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/SAPCND/GENERATOR293
- Access structure &1 was activated with a warning ?The SAP error message
/SAPCND/GENERATOR293 Access structure &1 was activated with a warning
typically indicates that an access structure in the SAP system was activated, but there were warnings during the activation process. This can happen in the context of SAP Condition Management, where access structures are used to define how conditions are accessed and evaluated.Cause:
The warning during the activation of the access structure can be caused by several factors, including:
- Inconsistent Data: There may be inconsistencies in the data used to define the access structure.
- Missing Fields: Required fields may be missing from the access structure definition.
- Incorrect Field Types: The data types of the fields used in the access structure may not match the expected types.
- Performance Issues: The access structure may not be optimized, leading to potential performance warnings.
- Deprecated Fields: Some fields used in the access structure may be deprecated or not recommended for use.
Solution:
To resolve the warning and ensure that the access structure is functioning correctly, you can take the following steps:
- Check the Activation Log: Review the activation log for the access structure to identify the specific warnings. This log will provide details on what caused the warnings.
- Review Access Structure Definition: Go to the access structure definition in the SAP system and check for any inconsistencies or missing fields. Ensure that all required fields are included and correctly defined.
- Adjust Field Types: Verify that the data types of the fields in the access structure match the expected types. Make any necessary adjustments.
- Optimize the Access Structure: If performance warnings are present, consider optimizing the access structure by reviewing the fields and their usage.
- Consult Documentation: Refer to SAP documentation or notes related to access structures and condition management for any specific recommendations or best practices.
- Test the Access Structure: After making changes, test the access structure to ensure it works as expected without warnings.
Related Information:
SE11
(Data Dictionary) to view and modify access structures, and SE80
(Object Navigator) for broader development tasks.If the warnings persist after following these steps, it may be beneficial to consult with your SAP Basis or ABAP team for further analysis and support.
Get instant SAP help. Sign up for our Free Essentials Plan.
/SAPCND/GENERATOR292
Complete communication structure &1 was activated with a warning
What causes this issue? Total communication structure &v1& was activated with a warning. A total communication structure is a normal structur...
/SAPCND/GENERATOR291
Deletion not possible. Additional table &1 still contains entries.
What causes this issue? Deletion of a scale table is not possible as it still contains entries.System Response This is a safety measure to prevent d...
/SAPCND/GENERATOR294
Condition table &1 was activated with a warning
What causes this issue? Condition table &v1& was activated with a warning. A condition table is a database table. It can only be activated if...
/SAPCND/GENERATOR295
Additional table &1 was activated with a warning
What causes this issue? Additional table &v1& was activated with a warning. An additional condition table is a database table. It needs to fu...
Click on this link to search all SAP messages.