Do you have any question about this error?
Message type: E = Error
Message class: /SAPCND/GENERATOR -
Message number: 076
Message text: Generation of enqueue structure &1 failed.
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/SAPCND/GENERATOR076
- Generation of enqueue structure &1 failed. ?The SAP error message
/SAPCND/GENERATOR076 Generation of enqueue structure &1 failed
typically occurs during the generation of the enqueue structure for a specific object in the SAP system. This error can arise due to various reasons, including issues with the underlying database, inconsistencies in the data dictionary, or problems with the enqueue server.Causes:
- Database Issues: There may be problems with the database that prevent the enqueue structure from being generated.
- Data Dictionary Inconsistencies: If there are inconsistencies in the data dictionary or if the object definitions are not correctly maintained, this error can occur.
- Lock Table Issues: Problems with the lock table or enqueue server can lead to this error.
- Authorization Issues: Lack of proper authorizations for the user executing the operation can also cause this error.
- System Configuration: Incorrect configuration settings in the SAP system can lead to enqueue generation failures.
Solutions:
- Check Database Status: Ensure that the database is running correctly and that there are no issues with connectivity or performance.
- Rebuild Enqueue Structure: You can try to regenerate the enqueue structure by using transaction code
SE11
(Data Dictionary) and checking the relevant object. If necessary, you can also use transactionSE14
to activate the database object.- Check for Inconsistencies: Use transaction
SE11
to check for inconsistencies in the data dictionary. You can also use transactionSE14
to check and repair database objects.- Review Authorizations: Ensure that the user has the necessary authorizations to perform the operation. Check the user roles and profiles.
- Check System Logs: Review the system logs (transaction
SM21
) and the developer trace (transactionST11
) for any additional error messages or warnings that could provide more context.- Restart Enqueue Server: If the enqueue server is not functioning correctly, consider restarting it. This can be done through transaction
SM50
orSM66
by finding the enqueue server process and restarting it.- Consult SAP Notes: Check the SAP Support Portal for any relevant SAP Notes that may address this specific error message or provide additional troubleshooting steps.
Related Information:
SE11
: Data DictionarySE14
: Database UtilitySM21
: System LogST11
: Developer TraceSM50
/ SM66
: Process OverviewIf the problem persists after trying the above solutions, it may be necessary to contact SAP support for further assistance.
Get instant SAP help. Start your 7-day free trial now.
/SAPCND/GENERATOR075
Enqueue structure &1 activated successfully.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SAPCND/GENERATOR074
Activation of enqueue structure &1 failed.
What causes this issue? Activation of enqueue structure &v1& failed. An enqueue structure is a normal structure. It must fulfil minimum consi...
/SAPCND/GENERATOR077
Generation of enqueue structure &1 completed successfully.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SAPCND/GENERATOR078
Generate enqueue structure &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.