Do you have any question about this error?
Message type: E = Error
Message class: /SAPCND/GENERATOR -
Message number: 030
Message text: Condition table &1 could be written into DDIC successfully.
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/SAPCND/GENERATOR030
- Condition table &1 could be written into DDIC successfully. ?The SAP error message
/SAPCND/GENERATOR030
indicates that there was an issue with writing a condition table into the Data Dictionary (DDIC). This error typically arises during the generation of condition tables in the SAP system, particularly when working with the condition technique in pricing or other areas.Cause:
The error can be caused by several factors, including:
- Authorization Issues: The user may not have the necessary authorizations to create or modify objects in the DDIC.
- Technical Issues: There may be technical problems with the SAP system, such as inconsistencies in the database or issues with the transport layer.
- Existing Objects: The condition table may already exist in the DDIC, leading to conflicts when trying to create it again.
- Data Dictionary Lock: The DDIC might be locked due to another process or user, preventing the creation of new objects.
- Incorrect Configuration: There may be issues with the configuration of the condition table itself, such as incorrect field definitions or data types.
Solution:
To resolve the error, you can take the following steps:
- Check Authorizations: Ensure that the user has the necessary authorizations to create and modify DDIC objects. You may need to consult with your SAP security team.
- Review Existing Objects: Check if the condition table already exists in the DDIC. If it does, you may need to modify it instead of trying to create a new one.
- Check for Locks: Use transaction
SM12
to check for any locks on the DDIC objects. If there are locks, you may need to wait for them to be released or contact the user who has locked the object.- Review Configuration: Double-check the configuration of the condition table to ensure that all fields and data types are correctly defined.
- Check System Logs: Review the system logs (transaction
SLG1
) for any additional error messages or warnings that may provide more context about the issue.- Transport Issues: If the issue is related to transport, ensure that the transport layer is functioning correctly and that there are no issues with the transport requests.
Related Information:
SE11
(Data Dictionary), SE14
(Database Utility), and SE78
(SAP ArchiveLink).If the issue persists after following these steps, it may be beneficial to consult with your SAP Basis team or reach out to SAP support for further assistance.
Get instant SAP help. Start your 7-day free trial now.
/SAPCND/GENERATOR029
Condition table &1 could not be written into DDIC
What causes this issue? Condition table &v1& could not be written to the DDIC. A condition table is a database table. It must fulfil minimum ...
/SAPCND/GENERATOR028
Object catalog entry could not be created for object &1.
What causes this issue? During generation of condition technique objects, an object catagory entry should be generated for one of these objects. This...
/SAPCND/GENERATOR031
Reading structure &1 has failed
What causes this issue? Reading of structure &v1& failed. This can happen when there is no active version of the structure in the DDIC.System...
/SAPCND/GENERATOR032
Reading the structure of table &1 failed
What causes this issue? Reading structure of table &v1& failed. This can happen when no active version of the table is present in the DDIC.Sy...
Click on this link to search all SAP messages.