Do you have any question about this error?
Message type: E = Error
Message class: /SAPAPO/OM_ERROR -
Message number: 235
Message text: Relative offsets for I/O nodes for sequence-dependent setup are forbidden
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/SAPAPO/OM_ERROR235
- Relative offsets for I/O nodes for sequence-dependent setup are forbidden ?The SAP error message
/SAPAPO/OM_ERROR235
indicates that there is an issue with the configuration of sequence-dependent setups in the Advanced Planning and Optimization (APO) module of SAP. Specifically, this error arises when relative offsets for input/output nodes are not allowed in the context of sequence-dependent setups.Cause:
The error typically occurs due to one of the following reasons:
Incorrect Configuration: The configuration of the production process or the setup of the resources may not be aligned with the requirements for sequence-dependent setups. This can happen if the relative offsets for the input/output nodes are incorrectly defined or not allowed.
Incompatible Settings: The settings for the production process may be incompatible with the sequence-dependent setup requirements. For example, if the system expects absolute offsets but relative offsets are defined, this error can occur.
Data Integrity Issues: There may be inconsistencies or errors in the master data related to the production process, such as the routing or the production version.
Solution:
To resolve the error, you can take the following steps:
Check Configuration:
- Review the configuration of the production process in the APO system. Ensure that the settings for sequence-dependent setups are correctly defined.
- Verify that the input/output nodes are set up correctly and that the offsets are defined as required (absolute vs. relative).
Adjust Offsets:
- If relative offsets are not allowed, consider changing the configuration to use absolute offsets instead. This may involve modifying the setup times or the sequence-dependent setup parameters.
Review Master Data:
- Check the master data related to the production process, including the routing and production versions. Ensure that all relevant data is consistent and correctly defined.
Consult Documentation:
- Refer to the SAP documentation for APO and sequence-dependent setups to understand the requirements and constraints related to offsets.
Testing:
- After making changes, test the configuration in a development or test environment to ensure that the error is resolved before moving to production.
Seek Support:
- If the issue persists, consider reaching out to SAP support or consulting with an SAP expert who specializes in APO for further assistance.
Related Information:
By following these steps, you should be able to identify the root cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
/SAPAPO/OM_ERROR234
Invalid value given for ApoIoOffsetRelType
INCLUDE /SAPAPO/OM_ERROR_GENERAL OBJECT DOKU ID TXError message extract from SAP system. Copyright SAP SE. ...
/SAPAPO/OM_ERROR233
Invalid value given for om_conti_io_scheduling
INCLUDE /SAPAPO/OM_ERROR_GENERAL OBJECT DOKU ID TXError message extract from SAP system. Copyright SAP SE. ...
/SAPAPO/OM_ERROR236
Continuous I/O nodes not allowed for sequence-dependent setup activities
INCLUDE /SAPAPO/OM_ERROR_GENERAL OBJECT DOKU ID TXError message extract from SAP system. Copyright SAP SE. ...
/SAPAPO/OM_ERROR237
Invalid value for OM_PEG_TYPE
INCLUDE /SAPAPO/OM_ERROR_GENERAL OBJECT DOKU ID TXError message extract from SAP system. Copyright SAP SE. ...
Click on this link to search all SAP messages.