Do you have any question about this error?
Message type: E = Error
Message class: RT - Monitoring infrastructure MSG and alert texts
Message number: 297
Message text: No parameters added to URL; standard URL is used
The method definition in transaction RZ21 (alert monitor methods)
specified that a function module should be called to change the URL
specified in the definition. The specification is made with the method
definition parameter PARAMETER_FUBA and the name of the function module
to call. Such function modules can be used, for example, to add
parameters to a script that is to be called by way of a URL.
The URL that was specified in the method definition will be passed
without alteration to the browser.
Ensure that the function module is available in the SAP system in which
you are working and that the function module has been activated.
Error message extract from SAP system. Copyright SAP SE.
RT297
- No parameters added to URL; standard URL is used ?The SAP error message RT297, which states "No parameters added to URL; standard URL is used," typically occurs in the context of SAP Web Application Server or when using SAP's Internet Communication Framework (ICF). This message indicates that a URL was generated for a web application, but no additional parameters were appended to it, leading to the use of a standard URL.
Cause:
- Missing Parameters: The most common cause is that the application or transaction you are trying to access does not have any parameters specified in the URL. This can happen if the application is expecting certain input parameters to be passed but none were provided.
- Configuration Issues: There may be a misconfiguration in the ICF service or the application that is supposed to handle the request.
- User Input: If the URL is generated based on user input, it could be that the user did not provide the necessary parameters.
Solution:
- Check URL Parameters: Ensure that the URL you are using includes all the required parameters. If you are manually constructing the URL, verify that you are appending the necessary parameters correctly.
- Review Application Logic: If you are developing or maintaining the application, check the logic that generates the URL. Make sure it correctly appends parameters based on the application's requirements.
- ICF Configuration: If you suspect a configuration issue, check the ICF settings for the service you are trying to access. Ensure that it is correctly configured to handle the expected parameters.
- Debugging: If you have access to the backend, consider debugging the application to see why parameters are not being passed. This may involve checking the code or logs for any errors or warnings.
- Documentation: Refer to the documentation for the specific SAP application or service you are using to understand what parameters are expected and how to format them correctly.
Related Information:
By following these steps, you should be able to identify the cause of the RT297 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
RT296
URL must begin with standard protocol. Enter = Continue
What causes this issue? You entered a URL that did not begin with a World Wide Web protocol that the system recognized. The system accepts the follow...
RT295
Error in HTML control; could not display URL
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...