Do you have any question about this error?
Message type: E = Error
Message class: RSSDA - BW HANA Smart Data Access
Message number: 123
Message text: Field &1: Conversion exit SNUMC does not support type DECIMAL FLOAT
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
RSSDA123
- Field &1: Conversion exit SNUMC does not support type DECIMAL FLOAT ?The SAP error message RSSDA123 indicates that there is an issue with the conversion exit
SNUMC
when it is applied to a field of typeDECIMAL FLOAT
. This error typically arises when there is an attempt to convert a decimal floating-point number using a conversion exit that is not designed to handle that data type.Cause:
- Data Type Mismatch: The
SNUMC
conversion exit is intended for character strings that represent numeric values, typically in a fixed-point format. When it encounters aDECIMAL FLOAT
type, it cannot process it, leading to the error.- Incorrect Field Definition: The field in question may be incorrectly defined in the data dictionary or in the program, leading to the use of an inappropriate conversion exit.
Solution:
- Check Field Definition: Review the field definition in the data dictionary (SE11) to ensure that the field is defined with the correct data type. If the field is supposed to be a numeric type, consider changing it to a compatible type (e.g.,
DECIMAL
orCHAR
).- Use Appropriate Conversion Exit: If you need to convert a
DECIMAL FLOAT
, you may need to implement a custom conversion routine or use a different conversion exit that supportsDECIMAL FLOAT
.- Modify the Program Logic: If the conversion exit is being called in a program, check the logic to ensure that it is only applied to fields that are compatible with
SNUMC
. You may need to add checks or conditions to prevent the conversion exit from being applied to incompatible types.- Consult Documentation: Review SAP documentation or help resources for more information on conversion exits and their appropriate usage.
Related Information:
If the problem persists after trying the above solutions, it may be beneficial to consult with an SAP technical consultant or refer to SAP support for further assistance.
Get instant SAP help. Start your 7-day free trial now.
RSSDA122
Field &1: Type DECIMAL FLOAT is not allowed as characteristic
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSSDA121
Field name with suffix &1 not allowed
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSSDA124
Field &1: Function TO_ALPHANUM supports a maximum of 127 characters
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSSDK001
&
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.