Message type: E = Error
Message class: RSQU - S-API after 4.0: Delta Queue, Real Time Update
Message number: 023
Message text: A consistent delta extraction is not possible
Consistent delta extraction is not possible since the system &v2& is
not connected to DataSource &v1&. This system is a BW system with
release 1.2. Detla data can only be distributed to several target
systems if all receiving systems have a BW release of 2.0 or higher.
The extraction process has been terminated.
Delete the assignment of DataSource &v1& to BW system &v2& before you
repeat the extraction process.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
RSQU023
- A consistent delta extraction is not possible ?The SAP error message RSQU023, which states "A consistent delta extraction is not possible," typically occurs in the context of SAP BW (Business Warehouse) when there are issues with delta extraction from a source system. This error indicates that the delta mechanism cannot ensure that the data being extracted is consistent, which can happen for several reasons. Causes of RSQU023 Inconsistent Delta Queue: The delta queue in the source system may have inconsistencies, possibly due to previous failed delta extractions or issues with the data load process. Data Changes: If there are changes in the data model or if the data in the source system has been modified (e.g., records deleted or updated) after the last delta extraction, it can lead to inconsistencies. Initialization Issues: If the initialization of the delta extraction was not completed successfully, it can cause problems for subsequent delta extractions. Missing Data: If the data that is supposed to be extracted
Get instant SAP help. Sign up for our Free Essentials Plan.
RSQU022
Queue management in BW cannot be deleted
What causes this issue? Queue management in the BW system &v1& cannot be deleted.System Response The system issues an error message and will...
RSQU021
Name & is too long to be used in the delta update
What causes this issue? The name &v1& is too long to be used in the delta update.System Response The maximum number of characters for the na...
RSQU024
Could not determine BW release of logical system '&1'
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSQU025
DDic structure & does not exist or is not active
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...