Do you have any question about this error?
Message type: E = Error
Message class: RSO_CTC - Message class for CTC related messages
Message number: 208
Message text: Automatically reset last attempt to clone delta queues in &1 for &2
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
RSO_CTC208
- Automatically reset last attempt to clone delta queues in &1 for &2 ?The SAP error message RSO_CTC208 indicates an issue related to the cloning of delta queues in the context of SAP BW (Business Warehouse) or SAP HANA. This error typically arises during the process of data extraction when the system attempts to clone delta queues but encounters a problem that prevents it from completing the operation successfully.
Cause:
The error message RSO_CTC208 can be caused by several factors, including:
Delta Queue Issues: There may be inconsistencies or problems with the delta queues that are being cloned. This could be due to previous failed attempts or data inconsistencies.
System Performance: If the system is under heavy load or if there are performance issues, the cloning process may time out or fail.
Configuration Issues: Incorrect configuration settings in the data source or in the BW system can lead to problems during the cloning process.
Locks or Conflicts: There may be locks on the delta queues or conflicts with other processes that are trying to access the same data.
Solution:
To resolve the RSO_CTC208 error, you can take the following steps:
Check Delta Queue Status: Use transaction codes like
RSA7
orRSC3
to monitor the status of the delta queues. Ensure that they are in a consistent state and that there are no outstanding requests.Reset Delta Queue: If you find that the delta queue is inconsistent, you may need to reset it. This can be done using transaction
RSA7
or by using the appropriate function module to reset the delta queue.Check for Locks: Use transaction
SM12
to check for any locks on the delta queues. If there are locks, you may need to release them.Review System Performance: Monitor system performance using transaction
ST03N
orSM66
to ensure that the system is not overloaded. If necessary, schedule the cloning process during off-peak hours.Reconfigure Data Source: If the issue persists, review the configuration of the data source and ensure that all settings are correct.
Check Logs: Review the application logs (transaction
SLG1
) for any additional error messages or warnings that may provide more context about the issue.Consult SAP Notes: Check the SAP Support Portal for any relevant SAP Notes that may address this specific error message or provide additional troubleshooting steps.
Related Information:
RSA7
, RSC3
, SM12
, ST03N
, and SLG1
for monitoring and troubleshooting.By following these steps, you should be able to diagnose and resolve the RSO_CTC208 error effectively. If the problem persists, consider reaching out to SAP support for further assistance.
Get instant SAP help. Start your 7-day free trial now.
RSO_CTC207
IDOC details updated
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSO_CTC206
Check not possible before delta queues have been cloned
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSO_CTC209
Previous logical system name &1 is not the same as current name &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSO_CTC210
ALE ports updated
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.