Do you have any question about this error?
Message type: E = Error
Message class: RSM2 - Monitor assistant help texts
Message number: 079
Message text: DS &1 LS &2 set to "BY-Passing PSA" (mandatory); no InfoPackages allowed
The DataSource &V1& from Logsys &V2& is set to 'BY-Passing PSA'.
Therefore this Datasource can no longer be loaded with an InfoPackage.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Use a DTP to load this DataSource into BW.
Error message extract from SAP system. Copyright SAP SE.
RSM2079
- DS &1 LS &2 set to "BY-Passing PSA" (mandatory); no InfoPackages allowed ?The SAP error message RSM2079 indicates that a DataSource (DS) and a Logical System (LS) are set to "By-Passing PSA" (Persistent Staging Area), which means that the data is being loaded directly into the target without being stored in the PSA first. This setting can lead to issues when trying to load data using InfoPackages, as the system does not allow InfoPackages to be used in this scenario.
Cause:
- By-Passing PSA Setting: The DataSource is configured to bypass the PSA, which is typically done for performance reasons or when the data is not needed to be stored in the PSA.
- InfoPackage Configuration: The InfoPackage you are trying to use is not compatible with the DataSource's configuration, as it expects to load data into the PSA first.
Solution:
Change DataSource Settings:
- Go to the DataSource in the SAP BW system.
- Check the settings for the DataSource and see if the "By-Passing PSA" option is enabled.
- If you want to use InfoPackages, you will need to disable the "By-Passing PSA" option. This will allow the data to be loaded into the PSA first.
Use Direct Load:
- If you intend to keep the "By-Passing PSA" setting, you will need to load data directly using a different method, such as using a process chain or a direct data load method that does not involve InfoPackages.
Check InfoPackage Settings:
- Ensure that the InfoPackage is correctly configured for the DataSource you are using. If the DataSource is set to bypass the PSA, you may need to create a new InfoPackage that is compatible with this setting.
Related Information:
By addressing the configuration of the DataSource and the InfoPackage, you should be able to resolve the error message RSM2079 and successfully load your data.
Get instant SAP help. Start your 7-day free trial now.
RSM2078
Error &1 from FM RSDS_DATASOURCE_SINGLE_GET for DS &2 LS &3
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSM2077
One line contains two identical entries
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSM2080
Cannot execute InfoPackage &1; DS &2 LS &3 set to "BY-Passing PSA"
What causes this issue? The DataSource &V2& from Logsys &V3& is set to 'BY-Passing PSA'. Therefore this DataSource can no l...
RSM2081
Report RSBATCH_WRITE_PROT_TO_APPLLOG not planned. See long text.
What causes this issue? The system issues an error message and will not allow you to continue with this transaction until the error is resolved. Syst...
Click on this link to search all SAP messages.